• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: Tornier Inc TORNIER PERFORM REVERSED PERIP SCREW 5.0MMX30MM STERILE; Shoulder prosthesis, reverse configuration

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

Tornier Inc TORNIER PERFORM REVERSED PERIP SCREW 5.0MMX30MM STERILE; Shoulder prosthesis, reverse configuration Back to Search Results
Catalog Number DWJ730
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Codes Unspecified Infection (1930); Pain (1994); Swelling/ Edema (4577)
Date of Event 08/19/2026
Type of Reportable Event Serious Injury
Event or Problem Description
As reported: "patient has re-presented to surgeon, following revision shoulder arthroplasty in (b)(6) 2026.Significant swelling and redness over wound, pain on movement.Wound re-opened, and surgeon concluded that the prosthetic joint was now infected.Decided to remove all prosthesis, as stage 1 of a 2-stage revision.Glenoid component was found to be very loose, easily removed as 1 x construct (revised at previous revision).Humeral component (not revised at previous revision) was found to be extremely well fixed.Humeral poly insert removed - significant wear noted (only been insitu since (b)(6) '26 revision).Proximal humeral vertical osteotomy was required to loosen and to break the bone / implant on growth.Stem eventually removed; osteotomy cabled back together with nice loops.Multiple tissue specimens collected; debridement; copious lavage attended; no antibiotic spacer implanted - gleno-humeral joint left dis-articulated.Plan - antibiotic regime until clinical markers indicate no infection, then the 2nd stage revision will be undertaken, using a "custom glenoid", to be manufactured by a competitor company.".
 
Additional Manufacturer Narrative
Once the investigation is completed, any additional information will be reported in a supplemental report.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
TORNIER PERFORM REVERSED PERIP SCREW 5.0MMX30MM STERILE
Common Device Name
Shoulder prosthesis, reverse configuration
Manufacturer (Section D)
Tornier Inc
10801 nesbitt avenue s
bloomington MN 55437
Manufacturer (Section G)
Tornier Inc
10801 nesbitt avenue s
bloomington MN 55437
Manufacturer Contact
dannielle stap
325 corporate drive
mahwah, NJ 07430
+1(201)831-5000
MDR Report Key50791181
Report Number0001649390-2026-00945
Device Sequence Number9570542
Product Code PHX
UDI-Device Identifier00846832091256
UDI-Public00846832091256
Combination Product (Y/N)N
Initial Reporter CountryAS
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Company Representative
Type of Report Initial
Report Date (Section B) 09/16/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Lay User/Patient
Device Catalogue NumberDWJ730
Device Lot NumberAH5355085
Was Device Available for Evaluation? Yes
Is the Reporter a Health Professional? No
Initial Date Received by Manufacturer 08/19/2026
Initial Report FDA Received Date09/16/2026
Was Device Evaluated by Manufacturer? (Y/N) No
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient SexMale
-
-