Model Number M635TU80020
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Code Asystole (4442)
Date of Event 09/11/2026
Type of Reportable Event Serious Injury
Event or Problem Description
It was reported that asystole occurred.A left atrial appendage (laa) closure procedure was being performed under intracardiac echocardiography (ice) and transesophageal echocardiography (tee) guidance using a watchman fxd double curve access system (was) and versacross connect.While the physician was coming down from the superior vena cava in preparation for transseptal puncture with both devices, the patient developed asystole lasting approximately 20 to 30 seconds.External pacing was initiated, and the patient subsequently returned to atrial fibrillation.Imaging confirmed no pericardial effusion, and the physician elected to proceed with the procedure.Prior to watchman closure device implantation, cardioversion was attempted but was unsuccessful in restoring sinus rhythm.The procedure was completed as planned.The patient remained stable with no further reported complications.The patient was discharged the same day.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
WATCHMAN FXD Curve? Access System
Common Device Name
system, appendage closure, left atrial
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
300 boston scientific way
marlborough MA 01752
Manufacturer (Section G)
Boston Scientific Corporation
multitenant #2, street #58 zon
cartago, 03 30106
CS   30106
Manufacturer Contact
mary crawford
4100 hamline ave n
arden hills, MN 55112
+1(651)440-0979
MDR Report Key50805549
Report Number2124215-2026-49501
Device Sequence Number18303779
Product Code DQY
UDI-Device Identifier00191506013813
Combination Product (Y/N)N
Initial Reporter StateAZ
Initial Reporter CountryUS
PMA/510(K) Number
K212228
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Health Professional,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 09/17/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Model NumberM635TU80020
Device Catalogue NumberM635TU80020
Device Lot Number0039217015
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 09/11/2026
Initial Report FDA Received Date09/17/2026
Date Device Manufactured04/29/2026
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient Age69 YR
Patient SexMale
-
-