MAUDE Adverse Event Report: Datascope Corp. Sensation Plus 7.5Fr. 40cc IAB with Accessories, US Only; System, Balloon, Intra-Aortic And Control

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

Datascope Corp. Sensation Plus 7.5Fr. 40cc IAB with Accessories, US Only; System, Balloon, Intra-Aortic And Control Back to Search Results
Model Number 0684-00-0568-01U
Medical Device Problem Codes Inappropriate Waveform (2536); Device Sensing Problem (2917); No Pressure (2994)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 08/29/2026
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Updated fields: b4, e1, g3, g6, h2, h11\ correction fields: b1, d10, g7, h6(type of investigation, investigation findings, investigation conclusions), please revert a1 and d8 to blank as these details were sent inadvertently in initial report.
 
Event or Problem Description
N/a.
 
Additional Manufacturer Narrative
Event site name: (b)(6).\ \ difficult/unable to monitor arterial pressure is a condition in which the intra-aortic balloon pump (iabp) cannot obtain a reliable arterial pressure waveform due to issues such as sensor failure (fiber optic iab calibration failure, disconnection, or fiber optic cable break), catheter lumen obstruction (e.G., clot, kink, or lumen damage), setup or equipment problems (e.G., improper zeroing, air bubbles, damping, or loose connections), or patient-related factors such as low pulse pressure or arrhythmias.In these situations, the arterial pressure signal may become inaccurate or unavailable for safe iabp operation.\ difficult/unable to monitor arterial pressure can occur due to one or more of the following factors:\ - blood clot (thrombus) formation within the inner lumen,\ - break in the inner lumen,\ - kink in the inner lumen,\ - fiber optic iab calibration failure or disconnection,\ - fiber optic cable break,\ - fiber optic cable kink,\ - transducer not properly zeroed or vented,\ - overdamped or flat arterial pressure waveform due to air bubbles or excessive tubing compliance,\ - loose or incorrect pressure cable connections,\ - off-label use.\  \ a sensor failure can occur due to one or more of the following probable causes:\ - optical sensor kink,\ - break in the sensor,\ - connector issue.\ \ this issue continues to be monitored within the manufacturer's quality system.
 
Event or Problem Description
It was reported by direct call from the customer to the emergency support program, that during use of sensation plus 40cc balloon catheter a poor-quality arterial waveform on the iabp monitor while using the fiberoptix (fo) signal as the ap source.The fo arterial waveform displayed a whip-like artifact with pressure readings of 52/20 mmhg (map 44) and augmentation of 62.Comparison with the bedside monitor using the radial arterial line showed stable pressures of 104/61 mmhg (map 80).Troubleshooting, including multiple flushes of the inner lumen, did not resolve the waveform artifact.Review of a chest x-ray confirmed the distal radiopaque marker was positioned between the 2nd and 3rd intercostal spaces.Technical support recommended switching the ap source from fo to the transducer and guided the clinician through the process.Following the change, appropriate arterial waveforms and pressure values were obtained.No patient harm or injury was reported.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
Sensation Plus 7.5Fr. 40cc IAB with Accessories, US Only
Common Device Name
System, Balloon, Intra-Aortic And Control
Manufacturer (Section D)
Datascope Corp.
15 law drive
fairfield NJ 07004
Manufacturer (Section G)
Datascope Corp.
15 law drive
fairfield NJ 07004
Manufacturer Contact
ewelina chorlowska
15 law drive
fairfield, NJ 07004
MDR Report Key50816169
Report Number2248146-2026-0001549
Device Sequence Number10218612
Product Code DSP
UDI-Device Identifier10607567109565
UDI-Public(01)10607567109565(10)3000526761(17)290205(11)260205
Combination Product (Y/N)N
Initial Reporter StateIL
Initial Reporter CountryUS
PMA/510(K) Number
K122628
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Health Professional
Initial Reporter Occupation Nurse
Type of Report Initial
Report Date (Section B) 09/18/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number0684-00-0568-01U
Device Catalogue Number0684-00-0568-01U
Device Lot Number3000526761
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 08/29/2026
Initial Report FDA Received Date09/18/2026
Was Device Evaluated by Manufacturer? (Y/N) No
Date Device Manufactured02/05/2026
Is the Device Labeled for Single Use? (Y/N) Yes
Usage of Device Initial
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
Unknown IABP.
Patient Age66 YR
Patient SexMale
Patient Weight207 LB
-
-