Model Number 3992609
Medical Device Problem Code Mechanics Altered (2984)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 09/02/2026
Type of Reportable Event Malfunction
Event or Problem Description
Information was received from the distibutor via a manufacturer representative regarding a device used for minimally invasive transf oraminal lumbar interbody fusion procedure.It was reported that during intra-op, the threaded connection spun freely without engaging or tightening, which prevented the cage from locking securely onto the insertion tool, and the original cage was set aside and qua rantined while a new implant was opened, which threaded and locked onto the inserter without issue.The procedure was completed successfully without patient injury.There were no patient symptoms reported.There were no further complications reported regarding the event.
 
Additional Manufacturer Narrative
G2: country of origin: taiwan.Medtronic submits this report to comply with fda regulations 21 cfr parts 4 and 803.Medtronic has made reasonable efforts to provide as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.Medtronic will submit a supplemental report if additional relevant information becomes known.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
CAPSTONE PTC¿ Spinal System
Common Device Name
INTERVERTEBRAL FUSION DEVICE WITH BONE GRAFT,
Manufacturer (Section D)
MSD Deggendorf Mfg
wertstrasse 17
deggendorf,de 94469
GM  94469
Manufacturer (Section G)
MSD Deggendorf Mfg
wertstrasse 17
deggendorf,de 94469
GM   94469
Manufacturer Contact
justin ellis
1800 pyramid place
memphis, TN 38132
+1(763)526-5677
MDR Report Key50850795
Report Number3011795235-2026-00061
Device Sequence Number9651824
Product Code MAX
UDI-Device Identifier00643169187436
Combination Product (Y/N)N
Initial Reporter CountryTW
PMA/510(K) Number
K172199
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Distributor
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial
Report Date (Section B) 09/22/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number3992609
Device Catalogue Number3992609
Device Lot Number10TJ
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 09/03/2026
Initial Report FDA Received Date09/22/2026
Date Device Manufactured10/08/2025
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-