MEDTRONIC PUERTO RICO OPERATIONS CO. SYNCHROMED II; PUMP, INFUSION, IMPLANTED, PROGRAMMABLE
|
Back to Search Results |
|
| Model Number |
8637-40 |
| Medical Device Problem Codes |
Filling Problem (1233); Device Ingredient or Reagent Problem (2910); Infusion or Flow Problem (2964); Insufficient Device Problem Information (3190)
|
| Health Effect - Clinical Codes |
Muscular Rigidity (1968); Pain (1994); Cramp(s) /Muscle Spasm(s) (4521)
|
|
Type of Reportable Event
|
Serious Injury
|
|
Event or Problem Description
|
|
Information was received from a manufacturer representative, patient, and healthcare provider regarding the patient who was receiving unknown baclofen via an implantable pump for intractable spasticity indications for use.It was reported that the physician called the manufacturer representative (rep) to discuss a problem during the patients' refill.Caller stated that the patient had reported increased spasms and spasticity and the pump was not working like it normally would.Caller stated that the physician did not say when this onset.Caller stated that the healthcare provider (hcp) went to fill the pump and they were able to aspirate a drop from the reservoir but were only able to insert 30ml.Caller stated that they were going to meet with the hcp and patient today, and they were going to take an x-ray of the pump.Caller stated that they will be referring the patient to the surgeon since the patient is due for a pump replacement soon and are not getting the same therapeutic efficacy.Additional information was later received from the rep.They added that the hcp aspirated 40ml from the reservoir, and filled it with 40ml.Caller stated that the physician accessed the catheter access port (cap) and pulled back 2ml of yellow-clear fluid.The hcp re-accessed the cap and pulled back an additional 2ml of more fluid that was not quite as yellow, and they felt resistance when retrieving the needle.The patient experienced the same symptoms as previously, including pain and increased spasticity, but no fever or other signs of infection.
|
| |
|
Additional Manufacturer Narrative
|
|
B3: event date is not known.Please see b5 for approximate date range, if applicable.Medtronic submits this report to comply with fda regulations 21 cfr parts 4 and 803.Medtronic has made reasonable efforts to provide as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.Medtronic will submit a supplemental report if additional relevant information becomes known.
|
| |
|
Search Alerts/Recalls
|
|
|