MAUDE Adverse Event Report: Lumenis Ltd SlimLine SIS EZ; Powered Laser Surgical Instrument

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

Lumenis Ltd SlimLine SIS EZ; Powered Laser Surgical Instrument Back to Search Results
Model Number 0644-021-01
Medical Device Problem Codes Thermal Decomposition of Device (1071); Nonstandard Device (1420)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 06/15/2026
Type of Reportable Event Malfunction
Event or Problem Description
It was reported that during a removal of kidney stone procedure, when the fiber was connected and the laser activation began, the fiber tip burned out.The case was completed with a different device without patient complications.Analysis of the returned device identified that the fiber tip was broken.
 
Additional Manufacturer Narrative
Upon receipt of this fiber at our quality assurance laboratory, this device was thoroughly analyzed.The visual inspection concluded the fiber was received in one piece; there were no defects on fiber body.However, microscopic inspection of the fiber determined that the tip was broken and that there were burn marks on the connector.Functional test found that the aim beam was dimmed and passed through in a round shape.The device history record (dhr) confirmed that the device met all material, assembly and performance specifications.A review of the slimline sis ez hazard analysis was completed and confirmed that the event of fiber cap/tip broken was defined in the risk documentation.This event type has been accounted for during product risk analysis to support acceptable risk benefit for the product.A review of the device instructions for use (ifu) was completed, the ifu states: the fiber face should be free of excessive pits, scratches, discoloration, or debris.Using the fiber with such defects may destroy the fiber and damage the laser.Inspect the fiber for kinks, punctures, fractures, or other damage.If the fiber appears damaged, do not use the fiber; return it to the supplier for replacement.And hold the fiber tip to a non-reflective surface, and ensure that a circular red/green spot appears.If the spot is not circular, cleave the fiber (see fiber tip renewal during operation for details).If the spot is weak or not visible, discard the fiber or return it to the supplier for replacement.Based on analysis results and information available, a conclusion code of cause traced to component failure was assigned to this investigation.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SlimLine SIS EZ
Common Device Name
Powered Laser Surgical Instrument
Manufacturer (Section D)
Lumenis Ltd
hakidma 6
yokneam 20692 04
IS  2069204
Manufacturer (Section G)
MOLEX LLC
18019 n 25th ave
phoenix AZ 85023
Manufacturer Contact
farshad fahimi
4100 hamline avenue north
building c
saint paul, MN 55112
MDR Report Key50860733
Report Number2124215-2026-50547
Device Sequence Number10053828
Product Code GEX
UDI-Device Identifier07290109145600
UDI-Public(01)07290109145600(17)300103(10)23250225
Combination Product (Y/N)N
Initial Reporter CountryGM
PMA/510(K) Number
K170121
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Other,Foreign,Health Professional,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 09/22/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number0644-021-01
Device Catalogue Number0644-021-01
Device Lot Number0023250225
Was Device Available for Evaluation? Yes
Date Returned to Manufacturer07/20/2026
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 09/02/2026
Initial Report FDA Received Date09/22/2026
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured02/03/2025
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-