| Model Number |
0148 |
| Medical Device Problem Code |
High impedance (1291)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
01/11/2009
|
|
Type of Reportable Event
|
Malfunction
|
|
Event or Problem Description
|
|
Boston scientific crm received information that this right ventricular (rv) defibrillation lead exhibited high pace impedance >2000 ohms.Impedance had been rising from approximately 1800 ohms in november to >2000 ohms now.No adverse patient effects have been reported.Additional information indicated that the lead continues to have high pacing impedance measurements.The physician is aware of these measurements and has decided to monitor the patient at this time.
|
| |
|
Event or Problem Description
|
|
Boston scientific crm received information that this right ventricular (rv) defibrillation lead exhibited high pace impedance >2000 ohms.Impedance had been rising from approximately 1800 ohms in november to >2000 ohms nsrli.No adverse patient effects have been reported.
|
| |
|
Event or Problem Description
|
|
Boston scientific crm received information that this right ventricular (rv) defibrillation lead exhibited high pace impedance >2000 ohms.Impedance had been rising from approximately 1800 ohms in november to >2000 ohms now.No adverse patient effects have been reported.
|
| |
|
Additional Manufacturer Narrative
|
|
All available information indicates that the lead remains in service.A boston scientific representative was contacted but was unable to provide any additional information.It was later reported that alerts continued for the high rv pace impedance.The physician was aware of the situation and has decided to monitor the patient at this lime.The physician did not want further notification of these alerts.There is no additional information available.If additional information becomes available this event will be updated.
|
| |
|
Additional Manufacturer Narrative
|
|
All available information indicates that the lead remains in service.A boston scientific representative was contacted but was unable to provide any additional information.Ii was later reported that alerts continued for the high rv pace impedance.The physician was aware of the situation and did not want further notification of these alerts.There is no additional information available.If additional information becomes available this even! will be updated.
|
| |
|
Additional Manufacturer Narrative
|
|
All available information indicates that the lead remains in service.A boston scientific representative was contacted but was unable to provide any additional information.It was later reported that alerts continued for the high rv pace impedance.The physician was aware of the situation and did not want further notification of these alerts.There is no additional information available.If additional information becomes available this event will be updated.This follow-up 001 report was not submitted previously.As per request by the fda on june 16, 2026 follow-up 001 has been resubmitted in an effort to release follow-up 002 from hold status.
|
| |
|