Catalog Number 04745914001
Medical Device Problem Code Incorrect, Inadequate or Imprecise Result or Readings (1535)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 08/31/2026
Type of Reportable Event Malfunction
Event or Problem Description
There was an allegation of questionable tina-quant albumin gen.2 - urine application results for 1 patient on a cobas 6000 c501 module.The initial result was 52.5 mg/l.The repeat result was 7.7 mg/l.Additional repeat results were 31.6 mg/l and 7.5 mg/l.The results on a cobas c311 on (b)(6) 2026 were 10.8 mg/l and 5.8 mg/l.The results on the c501 on (b)(6) 2026 were 6.8 mg/l and 7.1 mg/l.A precision test was performed with the original sample, yielding the following results: 25.9 mg/l, 44.8 mg/l, 41.0 mg/l, 17.2 mg/l, 13.9 mg/l.
 
Additional Manufacturer Narrative
The tina-quant albumin gen.2 - urine application reagent lot number is 926603, and the expiration date was not provided.A field service engineer (fse) replaced the rinse unit tubing, reagent nozzles, and a reagent valve.The fse thoroughly checked and cleaned all fluidic and vacuum lines,¿ including the tank.Qc recovery was within specifications after these actions.The investigation is ongoing.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
cobas 6000 c501 module
Common Device Name
CLINICAL CHEMISTRY ANALYZER
Manufacturer (Section D)
Roche Diagnostics
9115 hague road
indianapolis IN 46250 -045
Manufacturer (Section G)
Hitachi High Tech Corp.
882 ichige hitachinaka
ibaraki 312-8 504
JA   312-8504
Manufacturer Contact
natalie catton
9115 hague road
indianapolis, IN 46250
MDR Report Key50870263
Report Number1823260-2026-03904
Device Sequence Number21511828
Product Code JJE
UDI-Device Identifier04015630924707
UDI-Public04015630924707
Combination Product (Y/N)N
Initial Reporter CountryIN
PMA/510(K) Number
K060373
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Health Professional,User Facility
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial
Report Date (Section B) 09/23/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Catalogue Number04745914001
Was Device Available for Evaluation? Yes
Is the Reporter a Health Professional? Yes
Initial Date Received by Manufacturer 08/31/2026
Initial Report FDA Received Date09/23/2026
Was Device Evaluated by Manufacturer? (Y/N) Yes
Is the Device Labeled for Single Use? (Y/N) No
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Patient SexUnknown
-
-