It was reported "the day after the coolief procedure, the patient experienced pain, warmth, and increased effusion in the left knee, raising suspicion of an infection.Blood was observed in the synovial fluid; however, no accumulation of pus was identified.The procedure was performed using aseptic technique."
the patient underwent a bilateral coolief procedure on (b)(6) 2026.The patient developed left knee pain one day after the procedure and right knee pain two days after the procedure.The reported symptoms included pain and warmth in the left knee with a slight increase in the pre-existing knee effusion.Information regarding pain severity, erythema, fever, or other signs of infection was not available.A joint aspiration and synovial fluid examination were performed approximately three days post-procedure.The aspirated fluid reportedly contained calcium pyrophosphate crystals, and the fluid appearance was described as approximately 50% blood-tinged, with no evidence of pus accumulation.Based on the clinical presentation and synovial fluid findings, the treating physician diagnosed the event as a pseudogout attack and indicated that there was no causal relationship to the coolief device or procedure.No evidence of infection was reported.Treatment consisted of joint aspiration and oral colchicine therapy.No antibiotics, hospitalization, or surgical intervention were required.The patient subsequently improved, was discharged, and was referred to a local medical facility for follow-up care.Since no additional reports have been received, the patient is considered recovered.The procedure was reportedly performed using sterile technique with sterile gloves, draping, probe, and appropriate skin disinfection.
|
|
The actual complaint product was not returned for evaluation.A review of the device history record is not possible as no lot number was provided; therefore, the udi-pi is unavailable.The lot number was not provided by the customer.All information reasonably known as of 23-sep-2026 has been included in this health authority report.Should additional information be obtained, a follow-up health authority report will be provided.The information provided by avanos medical, inc.Represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to avanos medical, inc.Avanos medical, inc.Has no independent knowledge of the event reported but is relaying the information that was provided by the user facility where the incident occurred.This product incident is documented in the avanos medical, inc.Complaint database and identified as complaint (b)(4).This information is submitted pursuant to 21cfr803, in compliance with the medical device reporting requirement and should not be considered to be an admission that an avanos medical, inc.Product is defective or caused serious injury.
|