Model Number SC-8216-70
Medical Device Problem Codes High impedance (1291); Inappropriate/Inadequate Shock/Stimulation (1574)
Health Effect - Clinical Code Inappropriate Device Stimulation of Tissue (4928)
Date of Event 07/17/2019
Type of Reportable Event Serious Injury
Event or Problem Description
It was reported that the patient was only feeling stimulation when tilting neck to the right and strong jolts when moving the arms.It was also stated that the patient's spinal cord stimulator (scs) paddle leads had high impedance.The patient underwent a procedure wherein the ipg and paddle leads were replaced.
 
Additional Manufacturer Narrative
Block b3: approximated based on the date the manufacturer became aware of the event.Additional suspect medical device components involved in the event: model number/catalog number: sc-8216-50.Serial number: (b)(6).Batch/lot number: 16354325.Model/catalog description: artisan lead 50 cm.Unique identifier (udi) #: (b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
Artisan?
Common Device Name
Stimulator, Spinal-Cord, Totally Implanted For Pain Relief
Manufacturer (Section D)
BOSTON SCIENTIFIC NEUROMODULATION CORPORATION
25155 rye canyon loop
valencia CA 91355
Manufacturer (Section G)
Boston Scientific Corporation
25155 rye canyon loop
valencia CA 91355
Manufacturer Contact
ricardo amaro castro
25155 rye canyon loop
valencia, CA 91355
+1(320)800-7570
MDR Report Key50878646
Report Number3006630150-2026-07054
Device Sequence Number10690876
Product Code LGW
UDI-Device Identifier08714729779919
Combination Product (Y/N)N
Initial Reporter StateMO
Initial Reporter CountryUS
PMA/510(K) Number
P030017
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2014
Device Explanted Year2026
Reporter Type Manufacturer
Report Source Health Professional,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 09/24/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Lay User/Patient
Device Expiration Date08/30/2015
Device Model NumberSC-8216-70
Device Catalogue NumberSC-8216-70
Device Lot Number16321731
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 08/28/2026
Initial Report FDA Received Date09/24/2026
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient SexFemale
-
-