|
Product complaint # (b)(4)
date sent to the fda: 9/24/2026.H6 component code: g07002 - no device problem found.This report is being submitted pursuant to the provisions of 21 cfr, part 803, part 4 subpart b.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by ethicon, or its employees that the report constitutes an admission that the product, ethicon, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.Additional information was requested, the following was obtained:
did this issue contribute to any patient adverse event?
were there any unexpected outcomes or complications resulting from the prolonged surgery time?
how long, in minutes, did the surgery prolong?
which tissue was being sutured when the event occurred?
was additional dissection required in other organs/tissues other than the target tissue?
was there any change in the patient¿s post operative care due to the prolonged procedure?
please perform and document the follow up attempt for product return.Please provide tracking number,
issue did not contribute to a adverse event,
no unexpected outcomes,
approx.20 min,
abdominal aorta,
no other dissection needed,
no change in post op care,
ethicon rep came to pick up box of suture.H3 investigational summary: the product was returned to ethicon for evaluation.One opened packet with thirty four unopened samples were received.Product code 8534h.Following the sampling plan, a visual inspection was conducted on thirteen (13) samples.During the initial inspection of the needle-suture piece, no needle pull-off was observed.The swage and attachment areas were noted to be as expected.The suture was removed from the overwrap and examined along the strand.Adhesive residue and curling were observed during the evaluation.The functional test was performed using instron equipment and the pull force result meet with the requirements.As part of the ethicon quality process, all devices are manufactured, inspected, and released to approved specifications.The event described could not be confirmed as no issues related to pull off - suture needle were noted.Although no product defect was identified, there may have been other circumstances or issues that occurred during the use of the device that could not be replicated during the laboratory analysis.Additional complaint information monitoring for potential safety signals is conducted through complaint trending as part of post-market surveillance.D4: udi: as the lot number for the device involved in the event was not provided, the full udi is currently not available.
|