Model Number 72404013
Medical Device Problem Codes Mechanical Problem (1384); Nonstandard Device (1420); Material Puncture/Hole (1504)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 01/09/2026
Type of Reportable Event Serious Injury
Event or Problem Description
It was reported that the patient visited the hospital because his inflatable penile prosthesis (ipp) was not functioning properly.The patient underwent surgery two weeks later and upon inspection, a tear was identified in the right cylinder.All components were explanted and replaced.There were no patient complications reported.
 
Additional Manufacturer Narrative
Upon receipt at our quality assurance laboratory, ams 700 underwent a thorough analysis.The cylinders were microscopically inspected and leak tested.The first cylinder was found to have a detached outer sleeve, broken and detached fabric threads consistent with wear, and two holes in the inner tube caused by fatigue.The second cylinder exhibited tears at the fold locations in the proximal, middle, and distal sections of the cylinder.The first cylinder did not pass the leak test, however, the second one did.The pump was microscopically inspected, functionally and leak tested.The pump was microscopically inspected and subjected to functional and leak testing.Microscopic examination revealed that the pump kink resistant tubing (krt) was worn down to the filament.The pump did not pass activation testing but successfully passed leak testing.The reservoir was microscopically inspected and leak tested.Microscopic examination identified wear at a fold in the reservoir shell; however, no leaks were detected.The device history record (dhr) review confirmed that the device met all material, assembly and performance specifications.A review of the device instructions for use (ifu) was completed and did not reveal any evidence of device misuse, off label use, or failure to follow instructions.A risk review was completed and confirmed that the events of mechanical malfunction (leaks, incomplete inflation/ deflation, kinking) and device has a fluid leak were defined in the product risk documentation.This event type has been accounted for during analysis to support acceptable risk benefit for the product.Based on the available information and analysis results, the leak in the tube of the first cylinder, supports the reported clinical observations of cylinder hole/perforation, and device mechanical issue.Therefore, a conclusion code of cause traced to component failure was assigned to this investigation.This record was identified during a retrospective review of complaint events; an electronic medical device report (emdr) was not previously submitted per applicable reporting criteria.Boston scientific has opened a nonconforming events and prevention investigation ((b)(4)) to determine the potential cause for why an emdr was not previously submitted to the food and drug administration (fda) in accordance with boston scientific's established medical device reporting process and fda adverse event reporting requirements.Information gained through these investigation efforts will be utilized to take action(s), as necessary.Model number/catalog number: 72404310 serial number: n/a batch/lot number: 100258004 model/catalog description: pump ms unique identifier (udi) #: (b)(4) model number/catalog number: 72404161 serial number: n/a batch/lot number: 942347002 model/catalog description: reservoir 65ml pc unique identifier (udi) #: (b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
AMS 700 CXR
Common Device Name
prosthesis, penis, inflatable
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
300 boston scientific way
marlborough MA 01752
Manufacturer (Section G)
Boston Scientific Corporation
300 boston scientific way
marlborough MA 01752
Manufacturer Contact
farshad fahimi
4100 hamline avenue north
building c
saint paul, MN 55112
MDR Report Key50885563
Report Number2124215-2026-50935
Device Sequence Number9827136
Product Code JCW
UDI-Device Identifier00878953002705
UDI-Public(01)00878953002705(17)190724(10)892594005
Combination Product (Y/N)N
Initial Reporter CountryKS
PMA/510(K) Number
N970012
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2018
Device Explanted Year2026
Reporter Type Manufacturer
Report Source Other,Foreign,Health Professional,Distributor
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 09/24/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Lay User/Patient
Device Expiration Date07/24/2019
Device Model Number72404013
Device Catalogue Number72404013
Device Lot Number892594005
Was Device Available for Evaluation? Yes
Date Returned to Manufacturer02/25/2026
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 01/23/2026
Initial Report FDA Received Date09/24/2026
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured08/11/2014
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention; Hospitalization;
Patient Age78 YR
Patient SexMale
-
-