Model Number MI2355A
Medical Device Problem Codes Use of Device Problem (1670); Human-Device Interface Problem (2949)
Health Effect - Clinical Codes Laceration(s) (1946); Discomfort (2330); Vascular Dissection (3160); No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 09/23/2026
Type of Reportable Event Malfunction
Event or Problem Description
It was reported that during implant the leadless implantable pulse generator (ipg) dislodged after the tether was cut and was sat in mid right atrium at the tip of the delivery catheter. the device then became free of the tether and moved and was then observed in the right pulmonary artery (rpa). the delivery system was removed and attempted retrieval using large curve agilis catheter, gooseneck snare and deflectable diagnostic catheter, then al1 with wire to guide to the rpa branch.They were unable to get to the branch with the device with the wire, and on contrast injection no contrast reached the branch with the device in.Suspected dissection of rpa branch on fluoroscopy with small lacerations in the right upper rpa. the device embolized in rpa branch and the patient had occasional coughing and mild chest discomfort.It was also noted that the introducer was used more than six months after the use by date.The patient will be monitored with the device remaining in the patient. no further patient complications have been reported as a result of this event.
 
Additional Manufacturer Narrative
Medtronic submits this report to comply with fda regulations 21 cfr parts 4 and 803.Medtronic has made reasonable efforts to provide as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.Medtronic will submit a supplemental report if additional relevant information becomes known.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
Micra
Common Device Name
INTRODUCER, CATHETER
Manufacturer (Section D)
Medtronic, Inc.
8200 coral sea street ne
mounds view,ie
EI 
Manufacturer (Section G)
Medtronic, Inc.
8200 coral sea street ne
mounds view,ie
EI  
Manufacturer Contact
gerard torenvliet
8200 coral sea st ne
mounds view, MN 55112--439
+1(763)526-9277
MDR Report Key50895165
Report Number2182208-2026-54671
Device Sequence Number14910236
Product Code DYB
UDI-Device Identifier00643169359888
UDI-Public(01)00643169359888(17)210104(10)MI2355A
Combination Product (Y/N)N
Initial Reporter CountryUK
PMA/510(K) Number
K132030
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Health Professional,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 09/25/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date01/04/2021
Device Model NumberMI2355A
Device Catalogue NumberMI2355A
Device Lot NumberMI2355A
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 09/23/2026
Initial Report FDA Received Date09/25/2026
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexFemale
-
-