MEDTRONIC PUERTO RICO OPERATIONS CO. SYNCHROMED II; PUMP, INFUSION, IMPLANTED, PROGRAMMABLE
|
Back to Search Results |
|
| Model Number |
8637-40 |
| Medical Device Problem Codes |
Fluid/Blood Leak (1250); Infusion or Flow Problem (2964)
|
| Health Effect - Clinical Code |
Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available (4581)
|
|
Type of Reportable Event
|
Serious Injury
|
|
Event or Problem Description
|
|
Information was received from the healthcare provider (hcp) via the company representative (rep) regarding a patient receiving intrathecal baclofen (gablofen) 500 mcg/ml at 50 mcg/day via an implantable pump.It was reported that per the managing clinic, the patient developed unexpected withdrawal symptoms during normal use.Per the managing clinic, the patient experienced a fall (date unknown) prior to experiencing withdrawal symptoms.A catheter dye study was attempted (date unknown), but per the managing clinic the catheter could not be aspirated.The existing catheter was found to be leaking at or near the collet between the pump and spinal segments.A catheter revision was scheduled to troubleshoot the implanted system and revise if necessary.Upon opening the pocket, free fluid was observed around the pump.The surgeon then aspirated the catheter via the catheter access port of the old pump and 3ml of clear fluid was withdrawn.However, the surgeon also noticed a clear fluid welling up around the collet between the spinal and pump segments and opted to revise the catheter with a new 8784 revision kit.The pump was also replaced prophylactically, but no complaints were made regarding the pump.The issue resolved at the time of this report.
|
| |
|
Additional Manufacturer Narrative
|
|
Continuation of d10: product id 8780 lot# serial# (b)(6), implanted:
(b)(6) 2017, explanted:.Product type catheter section d information references the main component of the system.Other relevant device(s) are: product id: 8780, serial/lot #: (b)(6), ubd: (b)(6) 2018, udi#: (b)(4).H3.The returned pump was subjected to a series of standard tests that include but is not limited to visual inspection, alarm output, motor function, and dispense testing.The returned device passed all testing in the laboratory and no anomalies were identified.The returned catheter was subjected to a series of standard tests that include but is not limited to visual inspection, patency testing, and pressure testing.Analysis identified a kink in the catheter body.Analysis identified a hole in the catheter body.Medtronic submits this report to comply with fda regulations 21 cfr parts 4 and 803.Medtronic has made reasonable efforts to provide as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.Medtronic will submit a supplemental report if additional relevant information becomes known.
|
| |
|
Search Alerts/Recalls
|
|
|