Model Number 0684-00-0576-01U
Medical Device Problem Code Restricted Flow rate (1248)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 09/07/2026
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Updated fields: d9, g3, g6, h2, h3, h6 (medical device ¿ problem code, type of investigation, investigation findings, investigation conclusions), h11.\ \ the reported problem was most likely caused by a membrane leak that allowed blood to enter the balloon.Microscopic examination of the leak site revealed a whitish patch surrounding the defect.This appearance is characteristic of an abrasion mark and is consistent with damage caused by contact with calcified plaque within the aorta.The observed kink in the catheter tubing was also noted during evaluation.\ \ this issue continues to be monitored within the manufacturer¿s quality system.
 
Event or Problem Description
N/a.
 
Event or Problem Description
During an emergency support program call, a cvicu fellow reported a catheter restriction alarm during support with a sensation plus 8fr.50cc intra-aortic balloon (iab).The customer had turned the pump off, and therapy had been discontinued for approximately 30 minutes at the time of the call.Due to the duration of the pump being off and the associated risk of thrombus formation, the customer was advised to remove the iab catheter.The nature of the catheter restriction alarm was reviewed, and the customer confirmed that the plan was to remove the iab catheter.No patient harm or injury was reported.
 
Additional Manufacturer Narrative
Event site name: (b)(6).\ upon completion of the investigation into this event a follow up report will be submitted.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
Sensation Plus 8Fr. 50cc IAB with Accessories, US Only
Common Device Name
System, Balloon, Intra-Aortic And Control
Manufacturer (Section D)
Datascope Corp.
15 law drive
fairfield NJ 07004
Manufacturer (Section G)
Datascope Corp.
15 law drive
fairfield NJ 07004
Manufacturer Contact
ewelina chorlowska
15 law drive
fairfield, NJ 07004
MDR Report Key50911911
Report Number2248146-2026-0001573
Device Sequence Number5776378
Product Code DSP
UDI-Device Identifier10607567109633
Combination Product (Y/N)N
Initial Reporter StateOH
Initial Reporter CountryUS
PMA/510(K) Number
K112327
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Health Professional
Type of Report Initial
Report Date (Section B) 09/28/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number0684-00-0576-01U
Device Catalogue Number0684-00-0576-01U
Device Lot Number3000535319
Date Returned to Manufacturer09/21/2026
Is the Reporter a Health Professional? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 09/07/2026
Initial Report FDA Received Date09/28/2026
Was Device Evaluated by Manufacturer? (Y/N) No
Date Device Manufactured03/03/2026
Is the Device Labeled for Single Use? (Y/N) Yes
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-