Model Number APB-6-15-3D-SS
Medical Device Problem Codes Separation Failure (2547); Physical Resistance/Sticking (4012)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 08/19/2026
Type of Reportable Event Malfunction
Event or Problem Description
Medtronic received a report that an axium coil encountered resistance in the echelon catheter and failed to deploy.The echelon catheter was also found kinked.The patient was undergoing aneurysm embolization for treatment of a saccular, unruptured aneurysm located in the c6 segment with a max diameter of 3.69 mm and a 3.45 mm neck diameter.The accessed vessel was the femoral artery with a diameter of 6.5 mm.It was noted the patient's blood flow was normal, and vessel tortuosity was normal.It was reported that during the aneurysm procedure, when using the echelon to deliver the axium coil, the resistance was obvious during advancement.Upon continuing to push, after it was advanced into position with difficulty, the coil could not be deployed normally.The operator suspected an echelon issue.After removing the echelon, it was found that the tip end had kinked and could not be used.After replacing with a new echelon, coil advancement was smooth; however, after reaching the target position, it still could not be detached.Subsequently, a new coil was used instead; advancement was smooth and all were successfully deployed.The reported device and any accessory devices were prepared as indicated in the instructions for use (ifu).The catheter was flushed as indicated in the ifu.No patient symptoms or further complications were reported as a result of this event.
 
Additional Manufacturer Narrative
Medtronic submits this report to comply with fda regulations 21 cfr parts 4 and 803.Medtronic has made reasonable efforts to provide as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.Medtronic will submit a supplemental report if additional relevant information becomes known.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
AXIUM PRIME BRPL 3D
Common Device Name
DEVICE, VASCULAR, FOR PROMOTING EMBOLIZATION
Manufacturer (Section D)
Medtronic Mexico S. De R.L. De CV
av. paseo del cucapah #10510
tijuana,bc 22210
MX  22210
Manufacturer (Section G)
Medtronic Mexico S. De R.L. De CV
av. paseo del cucapah #10510
tijuana,bc 22210
MX   22210
Manufacturer Contact
justin ellis
9775 toledo way
irvine, CA 92618
+1(763)526-5677
MDR Report Key50915621
Report Number9617601-2026-05808
Device Sequence Number20277911
Product Code KRD
UDI-Device Identifier00847536038295
Combination Product (Y/N)N
Initial Reporter CountryCH
PMA/510(K) Number
K081465
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Health Professional,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 09/28/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model NumberAPB-6-15-3D-SS
Device Catalogue NumberAPB-6-15-3D-SS
Device Lot Number230911021
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 09/24/2026
Initial Report FDA Received Date09/28/2026
Date Device Manufactured04/21/2025
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexMale
-
-