W. L. Gore & Associates, Inc. GORE® VIABAHN® Endoprosthesis with HEPARIN Bioactive Surface; Stent, Superficial Femoral Artery
|
Back to Search Results |
|
| Catalog Number |
VBJR070502A |
| Medical Device Problem Codes |
Break (1069); Activation Failure (3270)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
09/06/2026
|
|
Type of Reportable Event
|
Malfunction
|
|
Event or Problem Description
|
|
On (b)(6) 2026, the patient underwent treatment for stenosis using a gore® viabahn® endoprosthesis with heparin bioactive surface (viabahn device) that was intended to be placed in the right external iliac artery.It was reported the viabahn device was advanced through a 7fr (55 cm) cook flexor ansel guiding sheath over a.018" (300 cm) abbott hi-torque steelcore guidewire.Reportedly, the target treatment site was not predilated but the viabahn device successfully reached the target treatment site.Upon attempted deployment, it was reported that the deployment line broke after an unknown length of the deployment line was pulled.It is unknown if there was any resistance felt.It was reported the endoprosthesis remained on the delivery catheter, fully constrained, and was removed in tandem with the delivery catheter through the sheath.Upon withdrawal, it was reported there was no endoprosthesis expansion noticed.Reportedly, there were no signs of delivery catheter breakage or detachment and no deployment line left inside the patient.It was reported there was no calcification and/or tortuous anatomy present.To complete the procedure, two new viabahn devices were selected for use.There was no patient harm reported.
|
| |
|
Additional Manufacturer Narrative
|
|
Cbas® heparin surface incorporates carmeda heparin manufactured from heparin sodium api, which is covalently bound to the device surface and is essentially non-eluting.W.L.Gore & associates, inc.(gore) is submitting this report to comply with 21 c.F.R.Part 803, the medical device reporting regulation.This report is based upon information obtained by gore, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.This report does not constitute an admission or a conclusion by fda, gore, or its associates that the device, gore or its associates caused or contributed to the event described in the report.In particular, this report does not constitute a legal admission by anyone that the product described in this report has any defects or has malfunctioned, as defined from a legal standpoint.These words are included in the report and are fixed items for selection created by the fda, to categorize the type of event solely for the purpose of reporting pursuant to part 803.This statement should be included with any information or report disclosed to the public under the freedom of information act.
|
| |
|
Search Alerts/Recalls
|
|
|