MEDTRONIC PUERTO RICO OPERATIONS CO. InterStim X; STIMULATOR, ELECTRICAL, IMPLANTABLE, FOR INCON
|
Back to Search Results |
|
| Model Number |
97800 |
| Medical Device Problem Code |
High impedance (1291)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
09/25/2026
|
|
Type of Reportable Event
|
Malfunction
|
|
Event or Problem Description
|
|
Information was received from a manufacturer representative regarding a patient who was implanted with an implantable neurostimulator (ins) for urinary/bowel dysfunction.It was reported that the reason for the call was the representative said they were doing a lead revision (see 709415697) and they tested the new lead and 2 of the electrodes came back with high impedance every time.The representative said they put the old battery on and it gave different impedances.The 1 and 2 electrodes were over 4,000 ohms.The representative put the new battery back in and they gave the same value of being high.The representative confirmed they tightened the set screw and tugged on the lead to make sure it was secure.The representative had not tried getting motor response from the lead with the external battery.During the call, the representative was able to get motor response on all 4 electrodes.Electrode 1 & 2 that had high impedances got motor response at 0.4 ma.Technical services (ts) reviewed with caller that the impedance was good, even though it registered high.Ts stated that if impedance was truly high then the patient would not have gotten motor response at 0.4 ma.The issue was not resolved through troubleshooting.Ts left the decision to replace the lead and/or neurostimulator up to the doctor.The rep later reported that all impedances cleared when they changed their position in the operating room and then a second time when impedances were checked again after the surgery closed.
|
| |
|
Additional Manufacturer Narrative
|
|
Section d references the main component of the system.Other medical products in use during the event include: brand name surescan; product id 978b128 (lot: va3b93c); product type: 0200-lead; implant date (b)(6) 2026; medtronic submits this report to comply with fda regulations 21 cfr parts 4 and 803.Medtronic has made reasonable efforts to provide as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.Medtronic will submit a supplemental report if additional relevant information becomes known.
|
| |
|
Search Alerts/Recalls
|
|
|