• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: Nobel Biocare AB Göteborg NobelActive Internal RP 4.3x13mm; Endosseous Dental Implant

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

Nobel Biocare AB Göteborg NobelActive Internal RP 4.3x13mm; Endosseous Dental Implant Back to Search Results
Catalog Number 34133
Medical Device Problem Code Failure to Osseointegrate (1863)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 02/10/2026
Type of Reportable Event Serious Injury
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
NobelActive Internal RP 4.3x13mm
Common Device Name
Endosseous Dental Implant
Manufacturer (Section D)
Nobel Biocare AB Göteborg
västra hamngatan 1
göteborg 41117
SW  41117
Manufacturer (Section G)
Nobel Biocare AB Göteborg
västra hamngatan 1
göteborg 41117
SW   41117
Manufacturer Contact
gayco meel
heierkerweg 1b
venlo 5928 -RM
NL   5928 RM
+031()623202508
MDR Report Key50940024
Report Number9611993-2026-136026
Device Sequence Number13195304
Product Code DZE
UDI-Device Identifier07332747160086
UDI-Public(01)07332747160086(10)12235217(17)281210
Combination Product (Y/N)N
Initial Reporter CountryIN
PMA/510(K) Number
K071370
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2026
Device Explanted Year2026
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Health Professional
Initial Reporter Occupation Dentist
Type of Report Initial
Report Date (Section B) 09/29/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Catalogue Number34133
Device Lot Number12235217
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Initial Date Received by Manufacturer 09/21/2026
Initial Report FDA Received Date09/29/2026
Was Device Evaluated by Manufacturer? (Y/N) No
Date Device Manufactured01/12/2024
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient Age56 YR
Patient SexMale
-
-