Datascope Corp. CARDIOSAVE HYBRID, 3.1 EDITION; System, Balloon, Intra-Aortic And Control Back to Search Results
Model Number 0998-00-0800-65
Medical Device Problem Code Gas/Air Leak (2946)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 02/24/2026
Type of Reportable Event Malfunction
Event or Problem Description
It was reported by the fse that the cardiosave intra-aortic balloon pump (iabp) helium gas rapidly decreased due to improper storage.After the helium cylinder was replaced with a new one, the issue reoccurred.The fse reported that they could not reproduce the issue.As a precaution, the gasket was replaced and it was confirmed that the helium was not leaking.There will be no part return.There was no patient involvement.
 
Additional Manufacturer Narrative
Event site name: (b)(6) hospital.Event site address: (b)(6).A getinge field service engineer (fse) inspected the unit and was able to verify the reported condition.No active leaks or reproducible faults were identified during the evaluation.It was suspected that the issue may have been related to the cylinder gasket.The fse replaced the gasket and monitored the system, confirming that the helium gas level remained stable following replacement.The results were satisfactory, and the unit was cleared for continued use.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
CARDIOSAVE HYBRID, 3.1 EDITION
Common Device Name
System, Balloon, Intra-Aortic And Control
Manufacturer (Section D)
Datascope Corp.
1300 macarthur blvd
mahwah NJ 07430
Manufacturer (Section G)
Datascope Corp.
1300 macarthur blvd
mahwah NJ 07430
Manufacturer Contact
ewelina chorlowska
1300 macarthur blvd
mahwah, NJ 07430
MDR Report Key50943039
Report Number2249723-2026-0004502
Device Sequence Number9499511
Product Code DSP
UDI-Device Identifier10607567113432
Combination Product (Y/N)N
Initial Reporter CountryJA
PMA/510(K) Number
K112372
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Health Professional,User Facility,Company Representative
Initial Reporter Occupation Biomedical Engineer
Type of Report Initial
Report Date (Section B) 09/30/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number0998-00-0800-65
Device Catalogue Number0998-00-0800-65
Was Device Available for Evaluation? Yes
Is the Reporter a Health Professional? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 02/24/2026
Initial Report FDA Received Date09/30/2026
Was Device Evaluated by Manufacturer? (Y/N) Yes
Is the Device Labeled for Single Use? (Y/N) No
Usage of Device Reuse
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
N/A.
Patient SexUnknown
-
-