• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: Medline Industries, LP MEDLINE; DBD-MATTRESS,SYSTEM,SUPRA DPS,LAL/ALT. P

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

Medline Industries, LP MEDLINE; DBD-MATTRESS,SYSTEM,SUPRA DPS,LAL/ALT. P Back to Search Results
Catalog Number MDT24SUPRADPS
Medical Device Problem Code Inflation Problem (1310)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 01/10/2025
Type of Reportable Event Malfunction
Event or Problem Description
It was reported that ¿her mattress the first 4 days it was working properly, after the fifth night mattress was inflated but not in full¿ and ¿she checked all connections and all is connected properly but not inflation in full.¿.
 
Additional Manufacturer Narrative
It was reported that the product problem/issue was not inflating; the complaint transcript states the mattress was working properly for the first 4 days and, after the fifth night, was inflated but not in full, with all connections connected properly but not inflation in full.Medline inflated the mattress with the pump provided and found no issues; the mattress inflated fully, soapy water was sprayed on the cell seams and found no leaking air, and all connectors were attached with no leaking air.The sample provided complaint has not been confirmed, and the cause was not confirmed with received sample.There was no reported death or serious injury associated with this event, and review of the complaint information as well as the results of the investigation indicated no need for further action at this time.There were no reports of death, serious injury, medical intervention, or follow up care.It has been determined that the reported event could cause or contribute to serious injury if it were to occur again.In an abundance of caution, this is a reportable event.If additional information becomes available this report will be reopened and reevaluated.This medical device report (mdr) is being submitted as part of retrospective review activities, which include review of historical data in accordance with regulations at 21 cfr part 803.The information included in this mdr reflects the information reasonably known to the manufacturer at the time of this retrospective review and submission.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
MEDLINE
Common Device Name
DBD-MATTRESS,SYSTEM,SUPRA DPS,LAL/ALT. P
Manufacturer (Section D)
Medline Industries, LP
three lakes drive
northfield IL 60093 -275
Manufacturer Contact
venkat gaanuthula
three lakes drive
northfield, IL 60093--275
MDR Report Key50947088
Report Number1417592-2026-54389
Device Sequence Number13349381
Product Code FNM
UDI-Device Identifier40080196372196
UDI-Public40080196372196
Combination Product (Y/N)N
Initial Reporter StateCA
Initial Reporter CountryUS
PMA/510(K) Number
K933965
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Company Representative
Type of Report Initial
Report Date (Section B) 09/29/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Catalogue NumberMDT24SUPRADPS
Was Device Available for Evaluation? Yes
Date Returned to Manufacturer02/06/2025
Is the Reporter a Health Professional? No
Was the Report Sent to FDA? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 01/10/2025
Initial Report FDA Received Date09/30/2026
Was Device Evaluated by Manufacturer? (Y/N) Yes
Is the Device Labeled for Single Use? (Y/N) No
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Reuse
Patient Sequence Number1
Patient SexFemale
-
-