| Model Number |
5076-45 |
| Medical Device Problem Codes |
Electrical /Electronic Property Problem (1198); Under-Sensing (1661)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
01/08/2025
|
|
Type of Reportable Event
|
Malfunction
|
|
Event or Problem Description
|
|
It was reported that during use of the cardiac resynchronization therapy defibrillator (crt-d), the ventricular tachycardia (vt) rhythm appears to fall in and out of detection possibly delaying therapy. at device classified termination of events, arrhythmia appears to continue beneath detection rate. the crt-d remains in use. the right atrial (ra) lead, atrial lead position check failed due to an unknown/unspecified reason.It was further reported that another ra lead atrial lead position check failed and it was due to intermittent and sudden undersensing.The lead remains in use with the physician closely monitoring lead trends.No patient complications have been reported as a result of this event.
|
| |
|
Event or Problem Description
|
|
It was reported that during use of the cardiac resynchronization therapy defibrillator (crt-d), the ventricular tachycardia (vt) rhythm appears to fall in and out of detection possibly delaying therapy. at device classified termination of events, arrhythmia appears to continue beneath detection rate. the crt-d remains in use. the right atrial (ra) lead, atrial lead position check failed due to an unknown/unspecified reason. it was further reported that the ra lead atrial lead position check failed due to intermittent and sudden undersensing.The lead remains in use with the physician closely monitoring lead trends.The patient is a participant in a clinical study.No patient complications have been reported as a result of this event.
|
| |
|
Additional Manufacturer Narrative
|
|
Continuation of d10: bis-is-15 adaptor and 6721m-50 defib epi patch implanted: (b)(6) 2021.Medtronic submits this report to comply with fda regulations 21 cfr parts 4 and 803.Medtronic has made reasonable efforts to provide as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.Medtronic will submit a supplemental report if additional relevant information becomes known.
|
| |
|
Additional Manufacturer Narrative
|
|
Correction: b5 medtronic submits this report to comply with fda regulations 21 cfr parts 4 and 803.Medtronic has made reasonable efforts to provide as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.Medtronic will submit a supplemental report if additional relevant information becomes known.
|
| |
|