Model Number 106531US
Medical Device Problem Code Disconnection (1171)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 09/09/2026
Type of Reportable Event Malfunction
Event or Problem Description
It was reported that the patient experienced numerous power cable disconnect alarms hours apart.It was said that the alarms occurred when the patient was walking, sitting, and lying down.The alarms were said to also have occurred before and after the patient fell while lying on a gurney.Upon initial interrogations the alarms did not appear to show on the system controller nor monitor.Log files were submitted for review and captured unusual power cable disconnect alarms while the patient was on battery power.The alarms appeared to be the result of relative state of charge (rsoc) invalid flags.All connections were checked and different batteries and two set of clips were tried but the alarms persisted.The alarms resolved when the system controller was exchanged.
 
Additional Manufacturer Narrative
No further information was provided.A supplemental report will be submitted once the manufacturer's investigation is complete.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
Thoratec® HeartMate 3¿ System Controller
Common Device Name
Ventricular (Assist) Bypass
Manufacturer (Section D)
Thoratec Corporation
6035 stoneridge drive
pleasanton CA 94588
Manufacturer (Section G)
Thoratec Corporation
6035 stoneridge drive
pleasanton CA 94588
Manufacturer Contact
fredric gold
6035 stoneridge drive
pleasanton, CA 94588
+1(781)852-8207
MDR Report Key50951041
Report Number2916596-2026-2920235
Device Sequence Number9552216
Product Code DSQ
UDI-Device Identifier00813024013235
Combination Product (Y/N)N
Initial Reporter StateCA
Initial Reporter CountryUS
PMA/510(K) Number
P160054
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Health Professional,Company Representative
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial
Report Date (Section B) 09/30/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Lay User/Patient
Device Expiration Date04/23/2026
Device Model Number106531US
Device Catalogue Number106531US
Device Lot NumberL00000709
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 09/09/2026
Initial Report FDA Received Date09/30/2026
Was Device Evaluated by Manufacturer? (Y/N) No
Date Device Manufactured07/18/2024
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient Age65 YR
Patient SexMale
Patient Weight180 LB
Patient RaceWhite
-
-