STRYKER ORTHOPAEDICS-MAHWAH SLIP TORQUE HANDLE; PROSTHESIS, KNEE, PATELLO/FEMOROTIBIAL, SEMI-CONSTRAINED, UNCEMENTED, POROUS, CO Back to Search Results
Catalog Number 6541-4-825
Device Problems Degraded (1153); Material Integrity Problem (2978)
Patient Problem No Patient Involvement (2645)
Event Date 11/19/2015
Event Type  malfunction  
Manufacturer Narrative
An event regarding santoprene handle degradation was reported.The event was confirmed.Conclusion: a capa was initiated because a series of complaints were received for triathlon instrumentation where green santoprene over-mold handles have been reported to be degrading, becoming sticky and unstable.This event was determined to be under the scope of the capa.Chemical and cytotoxicity tests showed the degraded santoprene is non-toxic.The ability to clean and sterilize the degraded instruments has not been compromised.
 
Event Description
It is reported by nurse of the hospital that after washing there is a sticky coating on the surface of the instruments.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SLIP TORQUE HANDLE
Type of Device
PROSTHESIS, KNEE, PATELLO/FEMOROTIBIAL, SEMI-CONSTRAINED, UNCEMENTED, POROUS, CO
Manufacturer (Section D)
STRYKER ORTHOPAEDICS-MAHWAH
325 corporate drive
mahwah NJ 07430
Manufacturer (Section G)
STRYKER ORTHOPAEDICS-MAHWAH
325 corporate drive
mahwah NJ 07430
Manufacturer Contact
joann lavatelli
325 corporate drive
mahwah, NJ 07430
2018315000
MDR Report Key5399555
MDR Text Key37151834
Report Number0002249697-2016-00232
Device Sequence Number1
Product Code MBH
Combination Product (y/n)N
PMA/PMN Number
K123486
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type health professional,other
Reporter Occupation Nurse
Type of Report Initial
Report Date 11/19/2015
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received01/29/2016
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue Number6541-4-825
Device Lot NumberBP3H05
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer12/22/2015
Is the Reporter a Health Professional? Yes
Date Manufacturer Received01/05/2016
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured06/03/2008
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Reuse
Patient Sequence Number1
Patient Outcome(s) Other;
-
-