Catalog Number 21347
Medical Device Problem Code Incorrect, Inadequate or Imprecise Result or Readings (1535)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
This report is being submitted as part of an fda request regarding supplemental reports that did not have an initial report on file.The initial report was originally submitted as 1950204-2016-00130 in error.A supplemental report for 1950204-2016-00130 has also been submitted to document the error and correction.
 
Event or Problem Description
A customer in (b)(6) contacted biomérieux to report a discrepant organism identification in association with the vitek® 2 anaerobic and corynebacteria (anc) identification (id) test kit.Propionibacterium species was misidentified as atopodium vaginae.Upon obtaining atopodium vaginae result for a male patient, an alternate method of testing (crystal) was employed.The result of propionibacterium agnes (or granuslosum) was obtained.There is no indication or report from the hospital or treating physician to biomérieux that the discrepant result led to any adverse event related to the patient's state of health.Culture submittals have been requested by biomérieux for internal investigation.An internal biomérieux investigation will be initiated.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
VITEK® 2 ANC TEST KIT
Common Device Name
VITEK® 2 ANC TEST KIT
Manufacturer (Section D)
BIOMÉRIEUX, INC.
595 anglum road
hazelwood MO 63042
Manufacturer (Section G)
BIOMÉRIEUX, INC.
595 anglum road
hazelwood MO 63042
Manufacturer Contact
matthew locus
595 anglum road
hazelwood, MO 63042
MDR Report Key5407895
Report Number1950204-2016-00004
Device Sequence Number11836366
Product Code JSP
UDI-Device Identifier03573026144364
UDI-Public03573026144364
Combination Product (Y/N)N
Initial Reporter CountryGM
PMA/510(K) Number
K910666
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Foreign,Health Professional,User Facility
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 03/24/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date05/04/2017
Device Catalogue Number21347
Device Lot Number244379420
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 12/29/2015
Supplement Date Received by Manufacturer12/29/2015
Initial Report FDA Received Date02/03/2016
Supplement Report FDA Received Date02/03/2016
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured07/07/2014
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-