• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: K2M, INC. MESA SPINAL SYSTEM; PEDICLE SCREW SPINAL SYSTEM

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

K2M, INC. MESA SPINAL SYSTEM; PEDICLE SCREW SPINAL SYSTEM Back to Search Results
Catalog Number 6201-05535
Medical Device Problem Code Device Issue (2379)
Health Effect - Clinical Code No Information (3190)
Date of Event 05/09/2016
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
A comprehensive investigation was immediately initiated on receipt of the complaint.The product was not returned to manufacturer for evaluation, and a thorough investigation could not be completed as no lot number has been identified/confirmed in this case.Since the screw remains in the patient no physical, material, chemical evaluation could be performed.If more information becomes available manufacturer will file a follow-up report at that time.
 
Event or Problem Description
It was reported to k2m, inc.On 05.10.2016 that two polyaxial screws were only able to be partially locked intra-op.
 
Additional Manufacturer Narrative
A comprehensive investigation was immediately initiated on receipt of the complaint.The product was not returned to manufacturer for evaluation, and a thorough investigation could not be completed as no lot number has been identified/confirmed in this case.Since the screw remains in the patient no physical, material, chemical evaluation could be performed, and the exact cause of the reported issue could not be ascertained.A general review of the manufacturing and inspection records did not reveal any contributing information/trends.Although no definitive root cause could be ascertained, damage to the lips of the outer collet due to instrument misalignment can cause the screw to become difficult to lock.
 
Event or Problem Description
It was reported to k2m, inc.On (b)(6) 2016 that two polyaxial screws were only able to be partialy locked intra-op.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
MESA SPINAL SYSTEM
Common Device Name
PEDICLE SCREW SPINAL SYSTEM
Manufacturer (Section D)
K2M, INC.
600 hope parkway se
leesburg VA 20175
MDR Report Key5698003
Report Number3004774118-2016-00035
Device Sequence Number843129
Product Code NKB
UDI-Device Identifier10888857163751
UDI-Public10888857163751
Combination Product (Y/N)N
Initial Reporter StateVA
Initial Reporter CountryUS
PMA/510(K) Number
K143334
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2016
Reporter Type Manufacturer
Report Source company representative
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 05/10/2016
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Physician
Device Catalogue Number6201-05535
Device Lot NumberUNKNOWN
Was Device Available for Evaluation? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 05/10/2016
Supplement Date Received by ManufacturerNot provided
Initial Report FDA Received Date06/03/2016
Supplement Report FDA Received Date06/28/2016
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-