ANIMAS CORPORATION ANIMAS VIBE; INSULIN INFUSION PUMP Back to Search Results
Device Problems Crack (1135); Loss of Power (1475)
Patient Problem No Known Impact Or Consequence To Patient (2692)
Event Type  malfunction  
Manufacturer Narrative
The pump has not been returned to animas for evaluation.If the device is returned, an evaluation shall be completed and a supplemental report will be filed.No conclusions can be made at this time.
 
Event Description
On (b)(6) 2016, the reporter contacted animas, alleging that the pump lost power, and the battery compartment was cracked.There was no indication that the product caused or contributed to an adverse event, and the reported issue was not resolved with troubleshooting.This complaint is being reported because the user may be unaware that the pump has lost power, leading to under delivery.
 
Manufacturer Narrative
Device evaluation: the pump was returned and evaluated by product analysis on 07/08/2016 with the following findings: animas has conducted a review of the device history record for this pump and confirmed that it was operating within required specifications at the time of release.A review of the pump black box data revealed multiple unexplained pump reboots, as well as cs 012, cs 052, and cs 054 call service alarms.During testing, the pump did not maintain power with the returned battery cap; the complaint was duplicated.The battery compartment threads were damaged, making it impossible to attach the cap to the pump to maintain power.The battery compartment was also observed to be cracked in two places.Unrelated to the complaint, the keypad cover was observed to be peeling and the pump casing was cracked near the display lens.(b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ANIMAS VIBE
Type of Device
INSULIN INFUSION PUMP
Manufacturer (Section D)
ANIMAS CORPORATION
200 lawrence dr
west chester PA 19380 3428
Manufacturer (Section G)
ANIMAS CORPORATION
200 lawrence dr
west chester PA 19380 3428
Manufacturer Contact
karin sargrad
200 lawrence dr
west chester, PA 19380-3428
4843561808
MDR Report Key5735105
MDR Text Key47707175
Report Number2531779-2016-12334
Device Sequence Number1
Product Code MDS
Combination Product (y/n)N
PMA/PMN Number
P130007
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type distributor,foreign
Type of Report Initial,Followup
Report Date 05/31/2016
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received06/20/2016
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Lay User/Patient
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer06/30/2016
Was the Report Sent to FDA? Yes
Device Age19 MO
Date Manufacturer Received05/31/2016
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured10/16/2014
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Unknown
Patient Sequence Number1
Patient Age33 YR
-
-