ANIMAS CORPORATION ANIMAS VIBE; INSULIN INFUSION PUMP Back to Search Results
Device Problem Battery Problem (2885)
Patient Problem No Known Impact Or Consequence To Patient (2692)
Event Type  malfunction  
Manufacturer Narrative
The pump has been returned to animas.Evaluation has not yet been completed.When evaluation is complete a supplemental report will be filed.No conclusion can be made at this time.
 
Event Description
On (b)(6) 2016, the reporter contacted animas, alleging a power (battery life) issue.This complaint is being reported as the issue may result in a long term cessation of insulin delivery if the user is unable to resolve the alarm.There was no indication that the product caused or contributed to an adverse event.
 
Manufacturer Narrative
Device evaluation: the device has been returned and evaluated by product analysis on 08/05/2016 with the following findings: frequent low battery warnings were observed.Short battery life was observed in the black box data.The pump electrical current draws were high.When the cgm (continuous glucose monitoring) board was disconnected from the pump, the current draws returned to normal.No damages were found to the cgm board.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ANIMAS VIBE
Type of Device
INSULIN INFUSION PUMP
Manufacturer (Section D)
ANIMAS CORPORATION
200 lawrence dr
west chester PA 19380 3428
Manufacturer (Section G)
ANIMAS CORPORATION
200 lawrence dr
west chester PA 19380 3428
Manufacturer Contact
karin sargrad
200 lawrence dr
west chester, PA 19380-3428
4843561808
MDR Report Key5794042
MDR Text Key50302794
Report Number2531779-2016-16135
Device Sequence Number1
Product Code MDS
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
P130007
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type consumer
Reporter Occupation Patient
Type of Report Initial,Followup
Report Date 06/25/2016
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received07/14/2016
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Lay User/Patient
Other Device ID Number011084040610007521800464816
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer07/06/2016
Is the Reporter a Health Professional? No
Was the Report Sent to FDA? Yes
Device Age1 MO
Date Manufacturer Received06/25/2016
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured05/16/2016
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Unknown
Patient Sequence Number1
Patient Age21 YR
Patient Weight124
-
-