Model Number N/A
Medical Device Problem Code Aspiration Issue (2883)
Health Effect - Clinical Code No Consequences Or Impact To Patient (2199)
Date of Event 07/11/2016
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
(b)(4).The event is currently under investigation.
 
Event or Problem Description
It was reported during a pericardial drainage fluid procedure that air was aspirated instead of fluid in the pericardium.A syringe was attached to another port of the same three-way stopcock to re-try the aspiration of fluid from the pericardium.Thus, resulting in successful aspiration.The procedure was finished with the device.There were not any reported adverse events to the patient.
 
Additional Manufacturer Narrative
Investigation - evaluation: a review of the complaint history, drawings, dimensional verification, device history record, instructions for use (ifu), manufacturing instructions, trends, quality control and visual inspection of the returned device was conducted during the investigation.One used pericardiocentesis catheter set was returned for evaluation that included clear connecting tubing with one fitting on each end with an attached three way stopcock.The device was visually examined then functionally leak tested.Two cracks are noted at base of stopcock; the first crack is measured 3 mm in length and the second is 4 mm in length.Stopcock was liquid leak tested and failed.A document based investigation evaluation was also performed as part of this investigation.There is no evidence to suggest the product was not made to specifications.Review of device history record shows no nonconforming events which could contribute to this failure mode.It should be noted there were no other reported complaints for this lot number.Based on the information provided, examination of the returned device and the results of our investigation, a definitive root cause of the observed cracks could not be determined.We will continue to monitor for similar complaints.Per the quality engineering risk assessment no further action is required.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PERICARDIOCENTESIS CATHETER SET
Common Device Name
GBX CATHETER, IRRIGATION
Manufacturer (Section D)
COOK INC
750 daniels way
bloomington IN 47404
MDR Report Key5821906
Report Number1820334-2016-00727
Device Sequence Number16303715
Product Code GBX
UDI-Device Identifier00827002032828
UDI-Public(01)00827002032828(17)170401(10)4928887
Combination Product (Y/N)N
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source distributor,foreign
Initial Reporter Occupation Health Professional
Type of Report Initial,Followup
Report Date (Section B) 07/11/2016
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model NumberN/A
Device Catalogue NumberC-PCS-850
Was Device Available for Evaluation? Yes
Type of Report(Section G)FDA Requested
Initial Date Received by Manufacturer 07/11/2016
Supplement Date Received by ManufacturerNot provided
Initial Report FDA Received Date07/26/2016
Supplement Report FDA Received Date02/23/2017
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-