• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: COOK INC CXI SUPPORT CATHETER; KRA CATHETER, CONTINUOUS FLUSH

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

COOK INC CXI SUPPORT CATHETER; KRA CATHETER, CONTINUOUS FLUSH Back to Search Results
Model Number N/A
Medical Device Problem Code Split (2537)
Health Effect - Clinical Code No Consequences Or Impact To Patient (2199)
Date of Event 08/22/2016
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The event is currently under investigation.
 
Event or Problem Description
It was reported that a catheter split during a venogram procedure on a female patient.Once removed it was noticed that the catheter had a split in it.The patient did not require any additional procedures nor experience any adverse events due to this occurrence.
 
Additional Manufacturer Narrative
(b)(4).Investigation - evaluation: a review of the complaint history, drawings, dimensional verification, device history record, instructions for use (ifu), manufacturing instructions, quality control and visual inspection of the returned device was conducted during the investigation.The device is shipped with an instruction for use (ifu) that describes the intended use, specific items are addressed such as: under precautions, "the catheter should not be advanced through an area of resistance unless the source of resistance is identified by fluoroscopy and appropriate steps are taken to reduce or remove the obstruction." the visual inspection of the returned device reported the device was returned for investigation.The catheter shaft was heavily dented 1.7 cm from the distal tip, and the reported split was located 4.5 cm from the distal tip.The shaft was close to being separated.No other damage was noted.There is no evidence to suggest the product was not made to specifications.Review of device history record shows no nonconforming events which could contribute to this failure mode.It should be noted there were no other reported complaints for this lot number.Due to the heavily dented shaft near the tip, it is possible that the procedure was difficult or the patient had a tortuous anatomy.As such, it is feasible to suggest that the split was caused by the device experiencing forces beyond its design.We will continue to monitor for similar complaints.Per the quality engineering risk assessment no further action is required.
 
Event or Problem Description
It was reported that a catheter split during a venogram procedure on a female patient.Once removed it was noticed that the catheter had a split in it.The patient did not require any additional procedures nor experience any adverse events due to this occurrence.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
CXI SUPPORT CATHETER
Common Device Name
KRA CATHETER, CONTINUOUS FLUSH
Manufacturer (Section D)
COOK INC
750 daniels way
bloomington IN 47404
MDR Report Key5956312
Report Number1820334-2016-00961
Device Sequence Number681194
Product Code KRA
UDI-Device Identifier00827002525474
UDI-Public(01)00827002525474(17)180814(10)6124275
Combination Product (Y/N)N
Initial Reporter StateUT
Initial Reporter CountryUS
PMA/510(K) Number
K072724
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 08/22/2016
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model NumberN/A
Device Catalogue NumberCXI-4.0-35-90-P-NS-DAV
Was Device Available for Evaluation? Yes
Type of Report(Section G)FDA Requested
Initial Date Received by Manufacturer 08/22/2016
Supplement Date Received by ManufacturerNot provided
Initial Report FDA Received Date09/16/2016
Supplement Report FDA Received Date11/16/2016
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-