Catalog Number IGTCFS-65-1-FEM-TULIP |
Device Problems
Insufficient Information (3190); Appropriate Term/Code Not Available (3191)
|
Patient Problems
Perforation of Vessels (2135); Disability (2371); No Information (3190)
|
Event Type
Injury
|
Manufacturer Narrative
|
(b)(4).Catalog #: unknown but referred to as a cook günther tulip filter.Expiration date: unknown as lot # is unknown.Mfr date unknown as lot # is unknown.Investigation is still in progress.
|
|
Event Description
|
Description according to short form complaint filled: it is alleged that "[pt] received a gunther tulip filter on (b)(6) 2011." patient outcome: it is alleged that [pt] was injured without further explanation.Hospital and medical records have been requested but not yet provided.
|
|
Manufacturer Narrative
|
(b)(4).Catalog#: unknown but referred to as a cook günther tulip filter.(b)(4).Information regarding the event has not been provided.It has not been possible to investigate this event based on the limited information, and we are closing the report until further information is received.If additional information is received, the report will be re-opened for further investigation.
|
|
Event Description
|
Description according to short form complaint filed: it is alleged that "[pt] received a gunther tulip filter on (b)(6) 2011." patient outcome: it is alleged that [pt] was injured without further explanation.Hospital and medical records have been requested but not yet provided.
|
|
Manufacturer Narrative
|
(b)(4).The event is currently under investigation.
|
|
Event Description
|
Per additional information provided on 02/13/2017: it is alleged that the filter is unable to be retrieve without further details.
|
|
Manufacturer Narrative
|
(b)(4).According to device history records, based on the lot number provided, there is no evidence to suggest that this device was not manufactured according to specifications or that the filter did not perform as intended, e.G., the prevention of recurrent pulmonary embolism (pe) via placement in the vena cava in the situations described in the ifu.
|
|
Manufacturer Narrative
|
Exemption number e2016032.(b)(4).Corrected data based on new information received: to product problem.To malfunction.It has not been possible to further investigate or evaluate this alleged event based on the limited information provided to date via the operative note stating "it is alleged that the filter is unable to be retrieved without further details." cook will reopen its investigation if further information is received warranting supplementation in accordance with 21 c.F.R.803.56.Filter retrieval is occasionally difficult.This is well-known from published scientific literature where filter retrievals are referred to as simple vs.Complex.Several case reports published in scientific literature describe complex cases with successful endovascular filter retrievals using additional, advanced techniques.No evidence to suggest that this device was not manufactured according to specifications and nothing indicates that the filter did not perform as intended, e.G.Intended for the prevention of recurrent pulmonary embolism (pe) via placement in the vena cava.Exemption number e2016032.(b)(4).Corrected data based on new information received: to product problem.To malfunction.It has not been possible to further investigate or evaluate this alleged event based on the limited information provided to date via the operative note stating "it is alleged that the filter is unable to be retrieved without further details." cook will reopen its investigation if further information is received warranting supplementation in accordance with 21 c.F.R.803.56.Filter retrieval is occasionally difficult.This is well-known from published scientific literature where filter retrievals are referred to as simple vs.Complex.Several case reports published in scientific literature describe complex cases with successful endovascular filter retrievals using additional, advanced techniques.No evidence to suggest that this device was not manufactured according to specifications and nothing indicates that the filter did not perform as intended, e.G.Intended for the prevention of recurrent pulmonary embolism (pe) via placement in the vena cava.
|
|
Manufacturer Narrative
|
Investigation is reopened due to additional information provided.It has not been possible to further investigate or evaluate this alleged event based on the limited information provided to date via the operative note stating "tulip: vc perforation, limited mobility, unable to retrieve, pain, suffering-updated sfc." cook will reopen its investigation if further information is received warranting supplementation in accordance with 21 c.F.R.803.56.Vena cava wall perforation is a known potential complication of vena cava filters.Both symptomatic and asymptomatic events have been reported.Among other causes, vena cava wall perforation may inadvertently be initiated by improper deployment, excessive force or manipulations near an implanted filter (e.G., a surgical procedure in the vicinity of a filter) and (or) procedures that involve other devices being passed through an in situ filter.There is a current debate in the published scientific literature on a differentiation between ivc wall perforation with and without clinical sequelae.E.G.Filter legs may be outside the contrast lumen on imaging without actually perforating the ivc wall (known as tenting) and with no clinical sequelae.In contrast, perforation of adjacent organs is reported with clinical sequelae.Filter retrieval is occasionally difficult.This is well-known from published scientific literature where filter retrievals are referred to as simple vs.Complex.Several case reports published in scientific literature describe complex cases with successful endovascular filter retrievals using additional, advanced techniques.Unknown if the reported "limited mobility, pain, suffering" are directly related to the filter and unable to identify a corresponding failure mode at this point in time.No relevant notes on neither device or lot number.Product is manufactured and inspected according to specifications.No evidence to suggest that this device was not manufactured according to specifications and nothing indicates that the filter did not perform as intended, e.G.Intended for the prevention of recurrent pulmonary embolism (pe) via placement in the vena cava.This report is required by the fda under 21 cfr part 803.This report is based on unconfirmed information submitted by others.Neither the submission of this report nor any statement made in it is intended to be an admission that any cook device is defective or malfunctioned; that a death or serious injury occurred; or that any cook device caused or contributed to; or is likely to cause or contribute to a death or serious injury if a malfunction occurred.Blank fields on this form indicate the information is unknown or unavailable, or unchanged.Exemption number (b)(4).William cook europe aps (manufacturer) is submitting this report on behalf of cook medical incorporated (cmi) (importer).Name and address for importer site: (b)(4).
|
|
Event Description
|
No additional information provided at this time.Timothy auran allegedly placed the filter.
|
|
Event Description
|
Additional information received identified the patient is alleging vena cava perforation/perforation greater than 3mm which was determined by a (b)(6) 2017computed tomography scan.The patient further alleges pain, suffering, loss of enjoyment of life, disability, scarring, disfigurement and limited or inability to engage in activities of daily living including running, lifting, using stairs, and using ladders.
|
|
Manufacturer Narrative
|
Exemption number e2016032.William cook europe aps (manufacturer) is submitting this report on behalf of cook medical incorporated (cmi) (importer).Name and address for importer site: cook medical incorporated (cmi), 400 daniels way, bloomington, in 47404, registration no.: 3005580113.Device codes: appropriate term/code not available (3191): perforation.This report includes information known at this time.A follow up report will be submitted should additional relevant information become available this report is required by the fda under 21 cfr part 803.This report is based on unconfirmed information submitted by others.Neither the submission of this report nor any statement made in it is intended to be an admission that any cook device is defective or malfunctioned; that a death or serious injury occurred; or that any cook device caused or contributed to; or is likely to cause or contribute to a death or serious injury if a malfunction occurred.
|
|