Model Number T177
Device Problem Premature Discharge of Battery (1057)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Date 09/13/2016
Event Type  Injury  
Manufacturer Narrative
The product is expected to be returned for analysis.This report will be updated upon return and completion of analysis.
 
Event Description
Boston scientific received information that this implantable cardioverter defibrillator (icd) required explant due to premature battery depletion (pbd).A revision procedure was performed wherein the device was explanted and replaced.No adverse patient effects were reported.
 
Manufacturer Narrative
Upon receipt at our post market quality assurance laboratory, a review of device memory revealed that the device declared elective replacement indicator (eri) after experiencing two consecutive charge times greater than the extended mid-life eri charge time limit.The observed rate of battery usage was compared to the expected rate of battery usage; the results indicated that the monitoring voltage was normal.Although the battery itself had not depleted prematurely, eri was triggered earlier than expected by extended charge times due to a higher-than-typical buildup of internal battery impedance.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
VITALITY 2
Type of Device
IMPLANTABLE CARDIOVERTER DEFIBRILLATOR
Manufacturer (Section D)
GUIDANT CRM CLONMEL IRELAND
guidant ireland
clonmel, tipperary ireland
Manufacturer (Section G)
GUIDANT CRM CLONMEL IRELAND
guidant ireland
clonmel, tipperary ireland
Manufacturer Contact
sonali vasekar
4100 hamline ave. n
st. paul, MN 
6515824786
MDR Report Key6024350
MDR Text Key57249579
Report Number2124215-2016-15830
Device Sequence Number1
Product Code KRG
Combination Product (y/n)N
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative
Reporter Occupation Physician
Type of Report Initial,Followup
Report Date 09/29/2016
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Device Operator Lay User/Patient
Device Expiration Date05/19/2010
Device Model NumberT177
Other Device ID NumberVITALITY 2 VR EL
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer09/26/2016
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? Yes
Initial Date Manufacturer Received 09/13/2016
Initial Date FDA Received10/12/2016
Supplement Dates Manufacturer ReceivedNot provided
Supplement Dates FDA Received10/14/2016
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured05/22/2009
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Treatment
0185; D141; T175; T177
Patient Outcome(s) Hospitalization; Life Threatening; Required Intervention;
Patient Age82 YR
-
-