| Catalog Number |
FEM14040 |
| Medical Device Problem Code |
Positioning Failure (1158)
|
| Health Effect - Clinical Code |
No Consequences Or Impact To Patient (2199)
|
| Date of Event |
10/25/2016
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
The device history records are being reviewed.The event is currently under investigation.The information provided by bard represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant was unable to provide further patient details.
|
| |
|
Event or Problem Description
|
|
It was reported that the endovascular stent graft could not be deployed in the subclavian vein.Reportedly, the tight stenosis had been pre-dilated.There was no reported patient injury.This is the same patient as reported in medwatch report # 9681442-2016-00301.
|
| |
|
Additional Manufacturer Narrative
|
|
The lot history records have been reviewed with special attention to the manufacturing and inspection of this product and the product was found to have met all specifications prior to shipment.As part of all complaint investigations, an attempt was made to evaluate the subject device as well as the device usage.In this case, no sample or image was provided for evaluation.Therefore, the reported event could not be reproduced.Potential contributing factors to the reported event have been considered.Previous investigations of similar complaints have been reviewed.This kind of event may be related to a difficult vessel anatomy or a challenging stent placement site.As reported, the stenosis was rather tight but pre-dilation of the lesion had been performed.Insufficient flushing of the device may be another contributing factor to this type of event.Not using an introducer sheath also may contribute to the reported event.As reported, no introducer sheath was used in this case.On the basis of the information available and as no sample was returned, a definite root cause for the reported event could not be determined.The ifu states that the device must be flushed with sterile saline.Also the ifu states: "the safety and effectiveness of the device when placed across a tight bend (.) has not been evaluated.Prior to stent graft deployment, ensure that the proximal (inflow) stent graft end is positioned in a straight section of the lumen to reduce the risk of higher deployment forces and possible endovascular system failure." and "do not kink the delivery catheter or use excessive force during delivery to the target lesion." furthermore, the ifu indicates that an introducer sheath of appropriate inner diameter is required for the procedure.Additionally, the ifu states: "if unusual resistance or high deployment force is encountered during stent graft deployment, abort the procedure, remove the delivery system and use an alternative device.".
|
| |
|
Event or Problem Description
|
|
It was reported that the endovascular stent graft could not be deployed in the subclavian vein.Reportedly, the tight stenosis had been pre-dilated.There was no reported patient injury.This is the same patient as reported in medwatch report # 9681442-2016-00301.
|
| |
|