MAUDE Adverse Event Report: ANGIODYNAMICS ANGIODYNAMICS / ANGIOVAC; CATHETER, CANNULA & TUBING, VASCULAR

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ANGIODYNAMICS ANGIODYNAMICS / ANGIOVAC; CATHETER, CANNULA & TUBING, VASCULAR Back to Search Results
Catalog Number H965251850
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Code Thrombosis (2100)
Date of Event 11/07/2016
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
Based on the confirmation in the email from the territory manager (tm), the cannula was a straight cannula (upn h965251850).Based on the attached ship history report (shr), the only lot ever shipped to this customer for this upn was 4943462.Although a ship history report (shr) was generated for this complaint, a review of the dhrs are not required for this event.There was no report of device malfunction or performance issue during the procedure.Duke empirical is a contract manufacturer of the angiovac cannula for angiodynamics, no informational scar is required.The angiovac cannula sample was not returned for evaluation since there was no reported device failure.It cannot, therefore, be determined if the cannula was used in accordance with its labeling.Based on the reported event description, the root cause for further medical intervention (surgery) was the doctor's decision due to a large clot observed in the right pulmonary artery.Directions for use (dfu) is provided with this device and contains the following statements: warnings: selection of the patient as a candidate for use with this device and for such procedures as it is intended is the physicians' sole responsibility.The outcome is dependent on many variables including, patient pathology, surgical procedure, and perfusion procedure/technique.The benefits of use of this device must be weighed against the risks including risks of systemic anticoagulation and must be assessed by the prescribing physician.As with all medical devices, this device and ancillary equipment are to be used by trained physicians only.Specifically, this device is to be used only by medical personnel experienced with initiating and monitoring extracorporeal bypass and by physicians trained and experienced using surgical and/or percutaneous (seldinger) vascular access techniques.Adverse events: this device, as do all extracorporeal blood vessel devices, has possible side effects, which include but are not limited to infections, blood loss, thrombus formation, embolic events, vessel, ventricular or valvular damage and complications of percutaneous or surgical insertion techniques.These may occur if the instructions for use are not followed.(b)(4).
 
Event or Problem Description
Elderly patient undergoing angiovac thrombectomy status post dvt and an occluded vena cava.Patient had a filter in place which was placed approximately 3 weeks prior to the case.During the pre-case plan there was a discussion of a supra-renal filter to prevent clot from going around the cannula and ending up in the patient's lungs.During the case however, the landing zone wasn't amenable for the supra-renal ivc filter placement.Access points for this case were right internal jugular for aspiration and left internal cannula for reinfusion.Additionally, the left femoral vein was accessed for imaging and ancillary devices.Initial flow rates were extremely poor in the peri-hepatic cava, only 500 cc/min at 1500 rpms.Angiodynamics clinical specialist voiced his concerns at this, especially since he couldn't account for this extremely low flow rate.The patient was then given a liter of saline to increase his circulating volume.The case then proceeded with a flow rate of 1.5l/min.The flow rates continued to be a problem throughout the case.A cleaner wire was used in the vena cava and a few minutes later the patient's end tidal co2 went down along with his oxygen saturation.Imaging of the pa showed a large clot in the rpa, so after some discussion with ct surgery the patient underwent an open thrombectomy.The patient did survive surgery and presumably will be ok.The angiovac cannula was not damaged during this case and the clinical specialist could observe no defects in the device.The used device was discarded at the hospital.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ANGIODYNAMICS / ANGIOVAC
Common Device Name
CATHETER, CANNULA & TUBING, VASCULAR
Manufacturer (Section D)
ANGIODYNAMICS
26 forest street
marlborough MA 01752
MDR Report Key6145665
Report Number2952363-2016-00012
Device Sequence Number19028492
Product Code DWF
UDI-Device IdentifierH965251850
UDI-PublicH965251850
Combination Product (Y/N)N
Initial Reporter StateIA
Initial Reporter CountryUS
PMA/510(K) Number
K142593
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,health
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 11/07/2016
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Physician
Device Expiration Date10/31/2017
Device Catalogue NumberH965251850
Device Lot Number4943462
Was Device Available for Evaluation? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 11/07/2016
Initial Report FDA Received Date12/05/2016
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Hospitalization; Required Intervention;
-
-