• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: COOK INC PERFORMER INTRODUCER; DYB INTRODUCER, CATHETER

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

COOK INC PERFORMER INTRODUCER; DYB INTRODUCER, CATHETER Back to Search Results
Model Number N/A
Medical Device Problem Code Leak/Splash (1354)
Health Effect - Clinical Code No Known Impact Or Consequence To Patient (2692)
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
(b)(4).The event is currently under investigation.
 
Event or Problem Description
It was reported the performer introducer valve was leaking during the procedure.The device was exchanged during the procedure.The patient had no adverse consequence due to this event.
 
Additional Manufacturer Narrative
Investigation - evaluation: a review of the complaint history, drawings, device history record, documentation, manufacturing instructions and quality control of the returned device was conducted during the investigation.The complaint device was not returned therefore, no physical examinations could be performed; however, a document based investigation evaluation was performed.No images were available and a review of the product was not performed as the device was not returned for evaluation.The device history record was reviewed and no non-conformances were noted.A search revealed this complaint to be the only reported complaint associated to the complaint lot number 6968919.Although the devices were not returned for evaluation, the root cause was determined to be manufacturing related.Measures have been previously initiated to address this issue.A quality engineering risk assessment has determined that no further action is required as it concluded that its occurrence is unlikely to lead to a serious health consequence to the patient.We will continue to monitor for similar complaints.
 
Event or Problem Description
It was reported the performer introducer valve was leaking during the procedure.The device was exchanged during the procedure.The patient had no adverse consequence due to this event.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PERFORMER INTRODUCER
Common Device Name
DYB INTRODUCER, CATHETER
Manufacturer (Section D)
COOK INC
750 daniels way
bloomington IN 47404
MDR Report Key6151023
Report Number1820334-2016-01431
Device Sequence Number16374128
Product Code DYB
UDI-Device Identifier00827002134959
UDI-Public(01)00827002134959(17)190512(10)6968919
Combination Product (Y/N)N
Initial Reporter StateFL
Initial Reporter CountryUS
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 11/10/2016
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model NumberN/A
Device Catalogue NumberRYCFW-6.0-35-6-CW
Was Device Available for Evaluation? No
Type of Report(Section G)FDA Requested
Initial Date Received by Manufacturer 11/10/2016
Supplement Date Received by ManufacturerNot provided
Initial Report FDA Received Date12/07/2016
Supplement Report FDA Received Date01/12/2017
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-