| Catalog Number |
AR-8933L-16 |
| Health Effect - Clinical Code |
No Known Impact Or Consequence To Patient (2692)
|
| Date of Event |
11/10/2016
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
Patient demographics (age at time of event, date of birth, gender, weight) were requested but not provided.No further patient information was provided at the time of this report or made available in response to follow-up communication.No additional adverse consequences have been reported from this event.This device is used for treatment.This is one of five submissions for the same patient event.The others are: 1220246-2016-00577 (cc100071 line (b)(4)), 1220246-2016-00578 (cc100071 line (b)(4)), 1220246-2016-00580 (cc100071 line (b)(4)), and 1220246-2016-00581 (cc100071 line (b)(4)).No device malfunction identified.At this time, it cannot be determined if the device may have caused or contributed to the patient's experience.An evaluation of the device cannot be performed as the device was not returned to arthrex.Device history record review revealed nothing relevant to this event.Additional information has been requested but not made available.This is the first complaint of this type for this part/lot combination.The potential cause(s) of this event will be communicated to the event reporter.If additional relevant information is received, a follow-up report will be submitted.Customer reported device discarded.
|
| |
|
Event or Problem Description
|
|
It was reported that the patient had undergone a previous 2nd tmt fusion on (b)(6) 2015.The surgeon was performing a 2nd tmt fusion revision surgery on (b)(6) 2016 due to non-union during which the following devices were explanted: ar-8952tt-04, lot 6791406 (cc100071 line (b)(4)), ar-8933l-24, lot w38572 (cc100071 line (b)(4)), ar-8933l-16, lot 1437750 (cc100071 line (b)(4)), ar-8933-26, lot 157946 (qty 2) (cc100071 line (b)(4)) and ar-8933-28, lot 139580 (cc100071 line (b)(4) ).To complete the revision procedure the surgeon was implanting an ar-8952ms-07, 2.4mm 7 hole low profile straight plate (cc100071 line(b)(4)) along with an ar-8724l-18, 2.4mm x 18mm low profile locking screw (cc100071 line (b)(4)) were being implanted in this revision surgery.A 1.7mm drill was used to create the pilot holes for the screws.The surgeon secured the plate with bb taks.He then inserted a 2.4mm locking screw, and the screw had cut through the plate and did not lock in.The 2.4mm plate was removed and the procedure was completed successfully with a 3.0 mm straight mtp plate and screws.No patient injury reported.
|
| |
|
Search Alerts/Recalls
|
|
|