Catalog Number UNKNOWN |
Device Problems
Difficult to Remove (1528); Unintended Movement (3026); Insufficient Information (3190)
|
Patient Problems
Perforation of Vessels (2135); No Information (3190)
|
Event Type
malfunction
|
Manufacturer Narrative
|
(b)(4).Lot#: unknown as information was not provided.Catalog#: unknown but referred to as a cook celect filter.Expiration date: unknown as lot# is unknown.Since catalog# is unknown the 510(k) could be either k061815, k073374 or k090140.Mfr date: unknown as lot# is unknown.(b)(4).Investigation is still in progress.
|
|
Event Description
|
Description according to short form complaint filed: it is alleged that "[pt] received a cook celect filter on (b)(6) 2011." patient outcome: it is alleged that [pt] was injured without further explanation.Hospital and medical records have been requested but not yet provided.
|
|
Manufacturer Narrative
|
(b)(4).Catalog#: unknown but referred to as a cook celect filter.Expiration date: unknown as lot# is unknown.Pma 510(k): since catalog# is unknown the 510(k) could be either k061815, k073374 or k090140.Mfg date: unknown as lot# is unknown.(b)(4).It has not been possible to investigate or evaluate this alleged event based on the limited information provided to date.Cook will reopen its investigation if further information is receiving warranting supplementation in accordance with 21 c.F.R.803.56.
|
|
Event Description
|
Description according to short form complaint filed: it is alleged that "[pt] received a cook celect filter on (b)(6) 2011." patient outcome: it is alleged that [pt] was injured without further explanation.Hospital and medical records have been requested but not yet provided.
|
|
Manufacturer Narrative
|
(b)(4).The event is currently under investigation.A supplemental report will be provided upon conclusion.
|
|
Event Description
|
This additional information was received 02/06/2017 and is as follows: patient alleges filter placed on (b)(6) 2011 for dvt.Patient alleges outcomes attributed to device include tilt (alleged per imaging on (b)(6) 2012), vena cava perforation (alleged per imaging on (b)(6) 2014), and that the device is unable to be retrieved.Patient alleges no attempts to retrieve device.
|
|
Manufacturer Narrative
|
Exemption number e2016032.William cook (b)(4) (manufacturer) is submitting this report on behalf of cook medical incorporated (cmi) (importer).Manufacturer reference # (b)(4).Corrected data: adverse event to product problem.Serious injury to malfunction.It has not been possible to further investigate or evaluate this alleged event based on the limited information provided to date via the operative note stating a celect filter was implanted and experienced tilt, vena cava perforation and unable to be retrieved.Cook will reopen its investigation if further information is received.Vena cava wall perforation is a known potential complication of vena cava filters.Both symptomatic and asymptomatic events have been reported.Among other causes, vena cava wall perforation may inadvertently be initiated by improper deployment, excessive force or manipulations near an implanted filter (e.G., a surgical procedure in the vicinity of a filter) and (or) procedures that involve other devices being passed through an in situ filter.There is a current debate in the published scientific literature on a differentiation between ivc wall perforation with and without clinical sequelae.E.G.Filter legs may be outside the contrast lumen on imaging without actually perforating the ivc wall (known as tenting) and with no clinical sequelae.In contrast, perforation of adjacent organs is reported with clinical sequelae.Filter tilt is a known risk in relation to filter implant reported in the published scientific literature and may occur during placement or during implanting period.Filter retrieval is occasionally difficult.This is well-known from published scientific literature where filter retrievals are referred to as simple vs.Complex.Several case reports published in scientific literature describe complex cases with successful endovascular filter retrievals using additional, advanced techniques.
|
|
Manufacturer Narrative
|
Exemption number e2016032.William cook europe aps (manufacturer) is submitting this report on behalf of cook medical incorporated (cmi) (importer).G1) name and address for importer site: (b)(6).Registration no.: (b)(4).Investigation is reopened due to additional information provided.Per quality engineering review, the additional information provided for this complaint does not change the previous investigation conclusion.Therefore, no new investigation activities will be conducted at this time.Cook will reopen its investigation if further information is received warranting supplementation in accordance with 21 c.F.R.803.56.This report includes information known at this time.A follow up report will be submitted should additional relevant information become available.This report is required by the fda under 21 cfr part 803.This report is based on unconfirmed information submitted by others.Neither the submission of this report nor any statement made in it is intended to be an admission that any cook device is defective or malfunctioned; that a death or serious injury occurred; or that any cook device caused or contributed to; or is likely to cause or contribute to a death or serious injury if a malfunction occurred.
|
|
Event Description
|
No additional information provided at this time.
|
|