Model Number 9500-27
Device Problems Use of Device Problem (1670); Invalid Sensing (2293)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Date 12/08/2016
Event Type  malfunction  
Manufacturer Narrative
(b)(4).
 
Event Description
Dexcom was made aware on (b)(6) 2016, that on (b)(6) 2016, there was a continuous glucose monitoring (cgm) inaccuracy compared to blood glucose (bg) meter that occurred. The sensor was inserted on the abdomen, on (b)(6) 2016. It was reported that patient used an alternate blood glucose testing site (site other than fingertips) and that the dexcom system was not calibrated at least every 12 hours. No additional event or patient information is available. The receiver data log was reviewed on 12/23/2016. The complaint of inaccurate cgm values was confirmed. A root cause could not be determined. Labeling indicates: do not use alternative blood glucose site testing (blood from your palm or forearm, etc. ) for calibration. Alternative site blood glucose values may be different than those taken from a fingerstick blood glucose value and may not represent the timeliest blood glucose value. Use a blood glucose value taken only from a fingerstick for calibration. Alternative site blood glucose values might affect the dexcom g5 mobile cgm system's accuracy. Also: calibrating less often than every 12 hours might cause sensor glucose readings to be inaccurate, resulting in you missing a severe low or high glucose event.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand NameDEXCOM G5 MOBILE CONTINUOUS GLUCOSE MONITORING SYSTEM
Type of DeviceCONTINUOUS GLUCOSE MONITOR
Manufacturer (Section D)
DEXCOM, INC.
6340 sequence drive
san diego CA 92121
Manufacturer (Section G)
DEXCOM, INC.
6340 sequence drive
san diego CA 92121
Manufacturer Contact
kipp durbin
6340 sequence drive
san diego, CA 92121
8582000200
MDR Report Key6215811
MDR Text Key63653474
Report Number3004753838-2016-93666
Device Sequence Number1
Product Code MDS
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
P120005
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type consumer
Reporter Occupation
Type of Report Initial
Report Date 12/08/2016
1 Device was Involved in the Event
0 Patients were Involved in the Event:
Date FDA Received12/30/2016
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator
Device Model Number9500-27
Device Catalogue NumberSTS-GL-011
Device Lot NumberASKU
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? No
Was the Report Sent to FDA?
Event Location No Information
Date Manufacturer Received12/08/2016
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No