| Model Number |
9004 |
| Medical Device Problem Code |
Adverse Event Without Identified Device or Use Problem (2993)
|
| Health Effect - Clinical Code |
Reocclusion (1985)
|
| Date of Event |
12/29/2016
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
The samples were not returned to the user facility; therefore, device evaluations are unable to be performed.A lot history review revealed 3 additional reocclusion complaints were associated with this lot.A review of the device history record (dhr) shows the lot was manufactured to specification.Conclusion: the actual samples were not received for evaluation.The dhr found nothing to indicate a manufacturing related cause for this event.The investigator assessed the event was not related to the study device or procedure.Note, the lutonix 035 drug coated balloon pta catheter is indicated for percutaneous transluminal angioplasty (pta), after pre-dilatation of de novo or restenotic lesions up to 150 mm in length in the native superficial femoral or popliteal arteries with reference vessel diameters of 4-7 mm.These lutonix dcb's were used to treat the stented lesion per the study requirements.The occurrence of reocclusion is an inherent risk of any pta procedure.If additional information becomes known to the manufacturer, a supplemental report will be provided will all relevant information.The information provided by bard represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bard.
|
| |
|
Event or Problem Description
|
|
It was reported through a clinical registry that during the index procedure, two lutonix percutaneous transluminal drug coated balloon (dcb) dilatation catheters were used to treat the target lesion located in the left superficial femoral artery (sfa).Approximately 4 months after the index procedure, the patient¿s left sfa stented area was reportedly reoccluded.A revascularization was performed and the hcp deemed it was successful.The investigator assessed the event was not related to the study device or procedure.The samples were discarded by the user facility and are not available for further evaluation.No adverse patient effects were reported.This is one of two products involved with the reported event and the associated manufacturers report number is 3006513822-2017-00003.
|
| |
|
Event or Problem Description
|
|
It was reported through a clinical registry that during the index procedure, two lutonix percutaneous transluminal drug coated balloon (dcb) dilatation catheters were used to treat the target lesion located in the left superficial femoral artery (sfa).Approximately 16 months after the index procedure, the patient¿s left sfa stented area was reportedly reoccluded.A revascularization was performed and the hcp deemed it was successful.The investigator assessed the event was not related to the study device or procedure.The samples were discarded by the user facility and are not available for further evaluation.No adverse patient effects were reported.This is one of two products involved with the reported event and the associated manufacturers report number is 3006513822-2017-00003.
|
| |
|
Additional Manufacturer Narrative
|
|
Corrected data: the event description had the months changed from "4" to "16." the udi no.Was changed from "(b)(4)" to "(b)(4)." the mdr contact person and email was changed to "(b)(6)" and "(b)(6)", respectively.The mdr contact person phone number was changed to "(b)(6)." the eval codes and descriptions were changed to align with fda guidance effective on july 6th, 2018.The evaluation method codes "3263 and 3317" were changed to "4115, 3331, 4110." the evaluation results code "213" was added.The evaluation conclusion code "92" was changed to "4310." the samples were not returned to the user facility; therefore, device evaluations are unable to be performed.A lot history review revealed 3 additional reocclusion complaints were associated with this lot.A review of the device history record (dhr) shows the lot was manufactured to specification.Conclusion: the actual samples were not received for evaluation.The dhr found nothing to indicate a manufacturing related cause for this event.The investigator assessed the event was not related to the study device or procedure.Note, the lutonix 035 drug coated balloon pta catheter is indicated for percutaneous transluminal angioplasty (pta), after pre-dilatation of de novo or restenotic lesions up to 150 mm in length in the native superficial femoral or popliteal arteries with reference vessel diameters of 4-7 mm.These lutonix dcb's were used to treat the stented lesion per the study requirements.The occurrence of reocclusion is an inherent risk of any pta procedure.If additional information becomes known to the manufacturer, a supplemental report will be provided will all relevant information.
|
| |
|