Catalog Number 05.001.021VET
Device Problem Device Stops Intermittently (1599)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Date 10/06/2016
Event Type  malfunction  
Manufacturer Narrative
(b)(4).The actual device has been returned and is currently pending evaluation.Once reliability engineering evaluates the device, a supplemental medwatch report will be sent accordingly.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Event Description
It was reported that during an unspecified veterinary surgical procedure, it was observed that the cable to console device had an intermittent activity; and that it had a possible broken wire.There was a five minute delay to the planned surgical procedure.A spare identical device was available for use.There were no reports of injuries, medical intervention or prolonged hospitalization.All available information has been disclosed.If additional information should become available, a supplemental medwatch report will be submitted accordingly.
 
Manufacturer Narrative
During subsequent follow-up with the customer, it was mentioned that the device was in use with an electric pen drive during the event.The actual device was returned for evaluation.Reliability engineering evaluated the device and observed that the device failed the test adapter test (faulty), there was corrosion on connector ends and there was a displaced pin on socket connector ( pushed in).Therefore, the reported condition was confirmed.The assignable root cause was determined to be due improper cleaning methods and improper handling, which are both classified as user error.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
CABLE 4M TO CONSOLE
Type of Device
INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED, MOTOR/ACCESS AND ATTACHMENT
Manufacturer (Section D)
SYNTHES OBERDORF
eimattstrasse 3
oberdorf CH443 6
SZ  CH4436
Manufacturer (Section G)
SYNTHES OBERDORF
eimattstrasse 3
oberdorf CH443 6
SZ   CH4436
Manufacturer Contact
michael cote
1302 wrights lane east
west chester, PA 19380
6107195000
MDR Report Key6269493
MDR Text Key65567908
Report Number8030965-2017-10320
Device Sequence Number1
Product Code HWE
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K043310
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type health professional,user faci
Reporter Occupation Biomedical Engineer
Type of Report Initial,Followup
Report Date 12/28/2016
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received01/23/2017
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue Number05.001.021VET
Device Lot Number9785464
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer01/04/2017
Is the Reporter a Health Professional? Yes
Date Manufacturer Received01/23/2017
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured01/26/2016
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage N