• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: COVIDIEN (IRVINE) PIPELINE FLEX EMBOLIZATION DEVICE; INTRACRANIAL ANEURYSM FLOW DIVERTER

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

COVIDIEN (IRVINE) PIPELINE FLEX EMBOLIZATION DEVICE; INTRACRANIAL ANEURYSM FLOW DIVERTER Back to Search Results
Model Number PED-475-30
Device Problem Adverse Event Without Identified Device or Use Problem (2993)
Patient Problem Therapeutic Response, Decreased (2271)
Event Date 01/11/2017
Event Type  Injury  
Manufacturer Narrative
The pipeline flex device will not be returned for evaluation as it remains implanted in the patient.Based on the reported information, there did not appear to have been any defect of the device during use.The event occurred in the patient post-procedure and its cause could not be conclusively determined from the reported information.Mdrs related to this event: 2029214-2017-00066.A good faith effort will be made to obtain the applicable information relevant to the report.If information is provided in the future, a supplemental report will be issued.
 
Event Description
Medtronic received report that a patient required retreatment approximately fifteen months after pipeline flex implantation.It was reported that two pipeline flex devices were implanted in the treatment of a left cavernous internal carotid artery (ica).There were no device issues reported during implantation.Fifteen months post-implantation, it was reported the aneurysm still remained so an additional pipeline flex was implanted.
 
Manufacturer Narrative
If information is provided in the future, a supplemental report will be issued.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PIPELINE FLEX EMBOLIZATION DEVICE
Type of Device
INTRACRANIAL ANEURYSM FLOW DIVERTER
Manufacturer (Section D)
COVIDIEN (IRVINE)
9775 toledo way
irvine CA 92618
Manufacturer (Section G)
COVIDIEN (IRVINE)
9775 toledo way
irvine CA 92618
Manufacturer Contact
tricha miles
9775 toledo way
irvine, CA 92618
9496801224
MDR Report Key6276350
MDR Text Key65709695
Report Number2029214-2017-00067
Device Sequence Number1
Product Code OUT
Combination Product (y/n)N
Reporter Country CodeJA
PMA/PMN Number
P100018.S011
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Reporter Occupation Physician
Type of Report Initial,Followup
Report Date 01/11/2017
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Health Professional
Device Expiration Date03/10/2018
Device Model NumberPED-475-30
Device Lot NumberA071807
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 01/11/2017
Initial Date FDA Received01/25/2017
Supplement Dates Manufacturer Received01/11/2017
Supplement Dates FDA Received09/29/2017
Date Device Manufactured03/11/2015
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Required Intervention;
Patient Age79 YR
-
-