Model Number IC-4593
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Code Unspecified Infection (1930)
Date of Event 09/21/2015
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Since there were no device deficiencies reported by the site, the device associated with this complaint will not be returned to zoll for physical evaluation.Based on the information provided by the site, there was no device deficiencies reported.According to the site, event was a pneumonia in post cardiac arrest patient, who was on ventilator.The site reported that event was related to the patient's clinical condition, and not related to study device or study procedure.Ventilator-associated pneumonia is a known complication during hospital stay, especially in immobilize intubated patients.Recent data analysis of (b)(4) trials, which enrolled 1885 patients, supports the conclusion that tm does not increase rate of pneumonia during hospital stay (1).(1.Crossley s, reid j, mclatchie r, hayton j, clark c, macdougall m, andrews pj.A systematic review of therapeutic hypothermia for adult patients following traumatic brain injury.Crit care.2014 apr 17;18(2):r75.Georgiou ap1, manara ar.Role of therapeutic hypothermia in improving outcome after traumatic brain injury: a systematic review.Br j anaesth.2013 mar;110(3):357-67.) a literature review led to a conclusion that th did not increase pneumonia rates in ohca patients.A systematic review of adverse events in patients undergoing therapeutic hypothermia after cardiac arrest demonstrated that th was associated with reduced in-hospital mortality, mortality at 1 month, and mortality at 6 months.There is a trend of a higher rate of pneumonia in the hypothermia groups than in the normothermia groups (rr, 1.18, 95% ci, 0.99 to 1.40, p=0.06; i2=30%).However, the trend was only observed in earlier trials (before 2006) and was not confirmed in later trials (after 2006).This may be due to the advancement in general ohca post-hospital management with time, an evolving th protocol as the technology was developed and improved, and/or better trial designs to reduce bias in the later trials (2).In the recent targeted temperature management at 33°c versus 36°c after cardiac arrest trial (ttm), no difference was observed for the rates of pneumonia at two different target temperatures (52% vs.46%, p=0.089) in unconscious survivors of out-of-hospital cardiac arrest of presumed cardiac cause (3).(2.Xiao g, guo q, shu m, xie x, deng j, zhu y, wan c.Safety profile and outcome of mild therapeutic hypothermia in patients following cardiac arrest: systematic review and meta-analysis.Emerg med j.2013 feb;30(2):91-100.) (3.Nielsen n, wetterslev j, cronberg t, erlinge d, gasche y, hassager c, horn j, hovdenes j, kjaergaard j, kuiper m, pellis t, stammet p, wanscher m, wise mp, åneman a, al-subaie n, boesgaard s, bro-jeppesen j, brunetti i, bugge jf, hingston cd, juffermans np, koopmans m, køber l, langørgen j, lilja g, møller je, rundgren m, rylander c, smid o, werer c, winkel p, friberg h; ttm trial investigators.Targeted temperature management at 33°c versus 36°c after cardiac arrest.N engl j med.2013 dec 5;369(23):2197-206.) literature search also showed that pneumonia did not impact mortality and neurological outcome in ohca patient.Early-onset pneumonia is a common complication after successful cardiopulmonary resuscitation regardless of hypothermia treatment.The onset of pneumonia may increase the length of mechanical ventilation duration and intensive care unit stay, but its influence on survival and neurological outcome is marginal15, 16.Prophylactic antibiotics were associated with a reduced incidence of pneumonia but a similar rate of good functional outcome (4).(4.Gagnon dj, nielsen n, fraser gl, riker rr, dziodzio j, sunde k, hovdenes j, stammet p, friberg h, rubertsson s, wanscher m, seder db.Prophylactic antibiotics are associated with a lower incidence of pneumonia in cardiac arrest survivors treated with targeted temperature management.Resuscitation.2015 jul;92:154-9.).
 
Event or Problem Description
A (b)(6) -year old female was enrolled in the frost study on (b)(6) 2015 at 15:26 with a past medical history of hypertension, coronary artery disease, significant valvulopathy, most recent pci on (b)(6) 20016, episode of myocardial infarction on (b)(6) 2002, heart failure, diabetes, transient ischemic attack approximately 2010 (unknown date and month), gi bleed in (b)(6) 2006 and (b)(6).The patient had a cardiac valve surgery on (b)(6) 1974.The patient never used tobacco or alcohol.On (b)(6) 2015 the patient had a witnessed out of office cardiac arrest at 12:57 at home.Before ems arrival she received bystander chest compressions and ventilation at 13:02, defibrillations at 13:03.Ems arrived at 13:25.The patient was intubated.Rosc was achieved at 13:30.At admission a pulse rate of 67 beats per minute, respiratory rate of 18 breaths per min, and bp value of 91/60 mm hg were recorded.On the same day of (b)(6), ivtm quattro catheter was inserted into the right femoral vein at 17:00 successfully and cooling was initiated at 20:00.Rewarming procedure began on (b)(6) 2015 at 20:00.Catheter was removed on (b)(6) 2015 at 10:00.On (b)(6) 2015 at 2:00, 6 hours post initiation of cooling procedure, 18 hours prior to rewarming procedure and 2 days prior to catheter removal, the patient experienced pneumonia.The patient was on intubation for 6 days from (b)(6) 2015.Vital signs were collected at the time of rewarming initiation on at 20:00 on (b)(6) and pulse rate of 72 beats per min, a bp value of 116/53 mmhg and, respiratory rate of 22 breaths per min were recorded.The patient was treated with invasive mechanical ventilation and with medications.Event was resolved without sequelae on (b)(6) 2016 at 22:00.On (b)(6) 2015, 19 days post enrollment, she was discharged to independent family support in stable condition.On (b)(6) 2015 patient completed 90 day follow up successfully.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ZOLL IVTM QUATTRO CATHETER
Common Device Name
CENTRAL VENOUS CATHETER
Manufacturer (Section D)
ZOLL CIRCULATION
2000 ringwood ave.
san jose CA 95131
MDR Report Key6296709
Report Number3010617000-2017-00084
Device Sequence Number395308
Product Code NCX
UDI-Device Identifier00849111075121
UDI-Public00849111075121
Combination Product (Y/N)N
Initial Reporter CountrySP
PMA/510(K) Number
K101987
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source foreign,health professional,s
Initial Reporter Occupation Health Professional
Type of Report Initial
Report Date (Section B) 02/01/2017
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Model NumberIC-4593
Device Catalogue Number8700-0660-40
Device Lot NumberUNKNOWN
Was Device Available for Evaluation? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 01/06/2017
Initial Report FDA Received Date02/02/2017
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Other; Required Intervention;
Patient Age65 YR
-
-