WILLIAM COOK EUROPE GÜNTHER TULIP VENA CAVA FILTER JUGULAR APPROACH; DTK FILTER, INTRAVASCULAR, CARDIOVASCULAR Back to Search Results
Catalog Number IGTCFS-65-JP-JUG-TULIP
Device Problems Kinked (1339); Failure to Advance (2524)
Patient Problem No Known Impact Or Consequence To Patient (2692)
Event Date 02/14/2013
Event Type  malfunction  
Manufacturer Narrative
(b)(4).Catalog# igtcfs-65-jp-jug-tulip.Similar to device under 510(k) k090140.(b)(4).Summary of investigational findings: investigation of returned device confirms that sheath is kinked and perforated.Filter appears fine.Under normal conditions the sheath is strong enough to accomplish the procedure, but it is seen before that the sheath may kink if somehow exposed to excessive force because of tortuous anatomy.If the filter is advanced through a kinked sheath, the filter legs may be prone to exceed the sheath wall.In this case it is concluded that the damages observed to the device is a consequence of tortuous patient anatomy and following resistance during insertion.No evidence to suggest that product was not manufactured according to specifications.Cook medical will continue to monitor for similar events.
 
Event Description
Description of event according to initial reporter: a patient experienced ivc filter placement with igtcfs-65-jp-jug-tulip.After right jugular vein was punctured, the sheath system was advanced to the target site successfully.However, since the curve of the neck vein was steep, the filter leg perforated the sheath when advancing the filter catheter ((b)(4)).The device was retrieved and replaced with another igtcfs-65-jp-jug-tulip ((b)(4)).However, this second filter catheter got stuck in the sheath and could not be passed through the sheath.Puncture site was changed and another manufacture's temporary filter was placed.Additional information received 27feb2013: when puncturing was conducted, the angle of the puncturing was almost 90° and the sheath got kinked.However, the physician did not notice the fact and advanced the filter, so the filter leg might have perforated the sheath.In addition, the physician did not change the angle/site of puncturing when using the second igtcfs-65-jp-jug-tulip.Therefore, it might not have passed through the sheath.Patient outcome: no information provided.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
GÜNTHER TULIP VENA CAVA FILTER JUGULAR APPROACH
Type of Device
DTK FILTER, INTRAVASCULAR, CARDIOVASCULAR
Manufacturer (Section D)
WILLIAM COOK EUROPE
4632 bjaeverskov
DA 
Manufacturer Contact
marianne hoey
sandet 6
bjaeverskov 4632
DA   4632
56868686
MDR Report Key6299238
MDR Text Key66468113
Report Number3002808486-2017-00229
Device Sequence Number1
Product Code DTK
UDI-Device Identifier00827002037731
UDI-Public(01)00827002037731(17)150906(10)E2974729
Combination Product (y/n)N
Reporter Country CodeJA
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type foreign,health professional,o
Reporter Occupation Physician
Type of Report Initial
Report Date 02/22/2013
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received02/03/2017
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue NumberIGTCFS-65-JP-JUG-TULIP
Was Device Available for Evaluation? Yes
Is the Reporter a Health Professional? Yes
Date Manufacturer Received02/27/2013
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured09/06/2012
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
-
-