Catalog Number 99460040
Medical Device Problem Code Migration or Expulsion of Device (1395)
Health Effect - Clinical Codes Pain (1994); No Code Available (3191)
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
(b)(4).Neither the device nor films of applicable imaging studies were returned to the manufacturer for evaluation.Therefore, we are unable to determine the definitive cause of the reported event.
 
Event or Problem Description
It was reported that on: (b)(6) 2015: the patient presented with a complaint of back pain.On (b)(6) 2015: the patient presented with pre-op diagnosis: lumbar degenerative disc (l3-l4) and underwent the following procedures: oblique approach for anterior lumbar interbody fusion, l3-l4 with discectomy and subsequent placement of peek cage, 14 mm x 50 mm x 22 mm with 6 degree lordosis packed with putty and subsequent instrumentation with a 40 mm straight plate.As per op-notes, ¿.We then went on the size with templates and then subsequently placed a peek cage 14 mm x 50 mm x 22 mm with 6 degree lordosis packed with putty.Then a 40 mm straight plate was placed after 5.5 x 35, two bolts were placed, one into the l2 and one at l3 and then 2 hex nuts were placed over the device anchoring in place.We then allowed the soft tissue fallback together after removal of our retractor.¿ the patient also underwent the following procedure: lateral lumbar interbody fusion with cage allograft and anterolateral plate l3-l4 for degenerative disc.As per op-notes, ¿.We then prepared for disc removal and fusion.We then used a series of curettes to dissect away the cartilaginous end plate and finally satisfied ourselves that the cartilage had been adequately removed.We sized a spacer sequentially up to 12 mm height and a 50 mm with 6 mm angle covered end plate to end plate in the ap position.We filled the spacer with allograft and impacted into position." the patient also underwent x-ray of lumbosacral 2 or 3 views.Impression: no lumbar spinal fusion hardware complication.On (b)(6) 2015: the patient was discharged from hospital.On (b)(6) 2015: the patient underwent x-ray of lumbosacral 2 or 3 views post-op.Impression: status post prior l4-s1 posterior decompression, interbody fusion with pedicle screws.There is fracture of the s1 screws in the mid portion.L3-l4 lateral fusion with interbody spacer placement.There is displacement of spacer, screws and lateral plate towards left of approximately 17 mm from the vertebral margin.Degenerative changes are noted.Mild anterolisthesis of l4 over l5 approxiamtely 4 mm, l5 over s1 of approximately 3mm.On (b)(6) 2015: the patient presented with lumbago and other specified pre-operative examination.On (b)(6) 2015: the patient presented with back pain.On (b)(6) 2015: the patient was pre-operatively diagnosed with malposition of the cage and loosening of left flank plate and fracture of s1 screws and underwent the following procedures: left lateral removal of l3-l4 plate and screws, reposition cage and insertion of screw.Remove posterior pedicel screws and rods l4-l5 and l5-s1; insertion of posterior pedicle screws and instrumentation l3-l4, l4-l5; posterolateral fusion with allograft dbm and allograft cancellous bone chips l3-l4; neuromonitoring; insertion of rh-bmp2.The patient underwent spine lumbosacral 2 or 3 views status post fusion for disc degeneration.Findings: ap and crosstable lateral portable views of the lumbar spine submitted.The dorsal aspects of the interpedicular screws are now identified involving s1 have been removed.Interpedicular screws involving l3 remains slight anterior listhesis of l4 on l5 and l5 on s1, not grossly changed.As per op-notes, ¿.I then removed the set screws at l4, l5 and s1 bilaterally.We removed the rods, which were peek and then finally removed screws, what was left from the sheared screws at s1 bilaterally, which announced to about a 1-inch screw as opposed to the 2.5 inch screws we placed.We left another inch of screws within the pedicle of s1 bilaterally.We then removed these screws that were set for peak rods at l4 and l5 and replaced them with screws measuring 6.5 mm in diameter x 45 mm length at each one¿¿.
 
Additional Manufacturer Narrative
Image review: multiple images were provided for patient with previous l4-s1 fusion who underwent l3-4 olif procedure.Postoperatively there is failure of the olif plate with interbody graft migration.We do not known the bony fusion status at l4-s1, and broken screws are seen at s1.I suspect that the three local fusion below the olif graft was solid enough to act as a lever arm and that the l3-4 level should have been augmented with posterior instrumentation initially.A good faith effort will be made to obtain the applicable information relevant to the report.If information is provided in the future, a supplemental report will be issued.
 
Additional Manufacturer Narrative
A good faith effort will be made to obtain the applicable information relevant to the report.If information is provided in the future, a supplemental report will be issued.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
CD HORIZON SPINAL SYSTEM
Common Device Name
APPLIANCE, FIXATION, SPINAL INTERVERTEBRAL BODY
Manufacturer (Section D)
WARSAW ORTHOPEDICS
2500 silveus crossing
warsaw IN 46582
MDR Report Key6325049
Report Number1030489-2017-00289
Device Sequence Number13563763
Product Code KWQ
UDI-Device Identifier00885074542553
UDI-Public00885074542553
Combination Product (Y/N)N
Initial Reporter StateIA
Initial Reporter CountryUS
PMA/510(K) Number
K053101
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2015
Device Explanted Year2015
Reporter Type Manufacturer
Report Source consumer
Initial Reporter Occupation Attorney
Type of Report Initial,Followup,Followup
Report Date (Section B) 04/20/2017
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Catalogue Number99460040
Was Device Available for Evaluation? No
Initial Date Received by Manufacturer 01/18/2017
Supplement Date Received by ManufacturerNot provided
04/20/2017
Initial Report FDA Received Date02/13/2017
Supplement Report FDA Received Date05/15/2017
09/29/2017
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient Age57 YR
Patient Weight106
-
-