Model Number H7493808012320
Medical Device Problem Code Failure to Advance (2524)
Health Effect - Clinical Code No Consequences Or Impact To Patient (2199)
Date of Event 12/15/2016
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
(b)(4).Device evaluated by mfr: returned product consisted of a quantum maverick balloon catheter.The balloon was tightly folded.There was contrast in the inflation lumen.The outer shaft, inner shaft, balloon and tip were microscopically examined.The hypotube shaft was completely separated 65 cm from the hub.The fracture faces were oval as if kinked prior to separation.There were numerous hypotube kinks.There was no evidence of any material or manufacturing deficiencies contributing to the damage and the reported difficulty.Inspection of the remainder of the device presented no other damage or irregularities.The manufacturing batch record review confirmed that the device met all material, assembly and performance specifications.The most probable root cause is operational context as device performance was limited due to anatomical procedural factors.(b)(4).
 
Event or Problem Description
Reportable based on device analysis completed on 03-feb-2017 it was reported that crossing difficulties were encountered.The 90% stenosed, 14x3.25mm target lesion was located in the severely tortuous and severely calcified left anterior descending (lad) artery.A 3.25mm x 12mm quantum¿ maverick¿ balloon catheter was advanced but failed to cross the lesion.The procedure was completed with another of the same device.No patient complications were reported and the patient's status was stable.However, returned device analysis revealed hypotube break.
 
Additional Manufacturer Narrative
(b)(4).
 
Event or Problem Description
It was further reported that the lesion size was 12 x 3.25 mm and not 14 x 3.25 mm as previously reported.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
QUANTUM¿ MAVERICK¿
Common Device Name
CATHETERS, TRANSLUMINAL CORONARY ANGIOPLASTY, PERCUTANEOUS
Manufacturer (Section D)
BOSTON SCIENTIFIC - MAPLE GROVE
one scimed place
maple grove MN 55311
MDR Report Key6344524
Report Number2134265-2017-01204
Device Sequence Number733262
Product Code LOX
UDI-Device Identifier08714729392682
UDI-Public(01)08714729392682(17)20190331(10)19024124
Combination Product (Y/N)N
Initial Reporter CountryCN
PMA/510(K) Number
P860019
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,distri
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 01/12/2017
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date03/31/2019
Device Model NumberH7493808012320
Device Catalogue Number38080-1232
Device Lot Number19024124
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer01/20/2017
Type of Report(Section G)FDA Requested
Initial Date Received by Manufacturer 02/03/2017
Supplement Date Received by ManufacturerNot provided
Initial Report FDA Received Date02/20/2017
Supplement Report FDA Received Date04/03/2017
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-