|
COOK ENDOSCOPY D.A.S.H.® PRE-LOADED WITH ACROBAT WIRE GUIDE; KNS, UNIT, ELECTROSURGICAL, ENDOSCOPIC (WITH OR WITHOUT ACCESSORIES)
|
Back to Search Results |
|
| Catalog Number |
DASH-ACRO-25-450 |
| Medical Device Problem Code |
Peeled/Delaminated (1454)
|
| Health Effect - Clinical Code |
No Consequences Or Impact To Patient (2199)
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
Concomitant medical products: cook dash extraction balloon with multiple sizing, dash-8.5-12-15.Investigation evaluation: our evaluation of the product said to be involved confirmed the report.There is wire guide coating damage near the distal end.A section at approximately 12.1 cm to 16 cm from the distal end has bare core wire exposed.The wire guide coating has folded over on itself toward the distal end at approximately 8.5 cm to 12.1 cm from the distal end.There is a slight bend at the distal end approximately 1.5 cm from the tip.Due to the condition of the returned device it cannot be determined if any section of the coating is missing.The sphincterotome associated with this device was included in the return of the device.A product-specific discrepancy that could have caused or contributed to this observation was not observed during our laboratory analysis.The wire guide subassembly device history record for the lot number said to be involved was reviewed.A discrepancy or anomaly was not observed with the product that was released for distribution.The device history record for the lot number said to be involved was reviewed.A discrepancy or anomaly was not observed with the product that was released for distribution.Investigation conclusion: a definitive cause for this observation could not be determined because the actual use conditions could not be duplicated in the laboratory setting.Due to a variety of clinical conditions such as patient anatomy, endoscope position or progression of disease state, we could not reproduce the actual conditions of product usage during our laboratory analysis.This limits our ability to conclusively determine a cause.The instructions for use instruct the user to do the following: "for best results, wire guide should be kept wet." failure to flush the wire guide can result in damage to the wire guide.The instructions for use instruct the user to do the following: "flush injection port with sterile water." failure to flush the injection port can result in damage to the wire guide.The instructions for use precaution the user that this product is not compatible with metal tip devices: "if preloaded, use of wire guide with metal tip ercp devices may result in damage to external coating and/or tip of wire guide." the reported observation can occur if the wire guide was used with an incompatible accessory device.If additional pressure is applied to the wire guide and/or accessory device(s) while moving the wire guide inside the accessory device(s), this could contribute to wire guide coating damage.Prior to distribution, all dash pre-loaded with acrobat wire guide sphincterotomes are subjected to a visual inspection to ensure device integrity.A review of the device history record confirmed that the lot said to be involved met all manufacturing requirements prior to shipment.Corrective action: corrective action is not warranted at this time based on the quality engineering risk assessment.Quality assurance will continue to monitor for complaint trends and reassess the risk assessment results as post market feedback continues to become available.
|
| |
|
Event or Problem Description
|
|
During an endoscopic retrograde cholangiopancreatography (ercp), the physician used a cook dash pre-loaded with acrobat wire guide sphincterotome.After several exchanges, the coating around the wire guide began to strip off revealing the core of the wire guide [coating damage].The technician noticed on fluoroscopy what looked like a spring at the tip of the wire guide.They removed it and realized the coating had stripped off.The wire guide was intact, no pieces or parts broke off, and there was nothing left behind in the patient nor was there any harm to the patient as a result of the wire stripping.They were able to use another wire and complete the procedure.
|
| |
|
Search Alerts/Recalls
|
|
|