• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: CODMAN AND SHURTLEFF, INC PRE-SHAPED PROWLER MICROCATHETERS; CATHETER, CONTINOUS FLUSH

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

CODMAN AND SHURTLEFF, INC PRE-SHAPED PROWLER MICROCATHETERS; CATHETER, CONTINOUS FLUSH Back to Search Results
Catalog Number 606151FX
Medical Device Problem Code Obstruction of Flow (2423)
Health Effect - Clinical Code No Consequences Or Impact To Patient (2199)
Date of Event 01/08/2017
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Conclusion: the prowler 14 microcatheters were not returned for analysis.Review of dhr for lot 17569016 found that 2 rejected unit (1 due to tight id and 1 wrinkle in ptfe ) may be related to the reported complaint.However, the dhr review confirmed that the rejected units were properly segregated and discarded.Controls are in place to detect such nonconformities.No other issues were noted that were considered potentially related to the reported complaint.The resistance between the galaxy coils and the prowler 14 microcatheter could not be confirmed without product return for analysis.The root cause of the event could not be determined based on the information received.There was no evidence to suggest the events were related to a manufacturing issue; therefore, no corrective actions will be taken at this time.This is 1 of 4 mdr reports being submitted for this complaint, with associated report numbers of 3008264254-2017-00015, 3008264254-2017-00014, 3008264254-2017-00022 and 3008264254-2017-00021.Corrected data: the initial information for this compliant was submitted in mdr report number 3008264254-2017-00014 on 2/6/2017.There were 2 devices with the same malfunction and same catalog and lot numbers.Both of those devices were reported on mdr 3008264254-2017-00014.This mdr is being sent as a correction to separate the devices into separate mdr reports, and to submit the complaint conclusion.
 
Event or Problem Description
It was reported by a healthcare professional that during a coiling procedure of a pcom aneurysm, the physician was unable to push two 4 x 12 galaxy coils (640cf0412/175514192) into two prowler 14 microcatheters (606151fx/17669016), and the coils and catheters were replaced.The physician was unable to advance the galaxy delivery system and experienced a lot of friction during withdrawal.The coil was contained inside of the sheath as the physician had not yet advanced it.With some force, the physician was able to pull the galaxy coil out of the prowler 14 microcatheter.The physician discarded both the galaxy coil and the prowler 14 microcatheter and began the process again with the second galaxy coil 4x12 and prowler 14 microcatheter.The same issue happened again; the coil would not advance as the physician said it became stuck in the microcatheter and they had trouble pulling it back out.The physician discarded the second galaxy coil 4x12 and prowler 14 microcatheter and completed the procedure with a third prowler 14 microcatheter and galaxy 3.5x9 coil.The difficulty occurred at the distal part of the body of the catheter; the galaxy coils were able to be advanced to the distal portion of the microcatheter.The galaxy coils and prowler 14 microcatheters were removed together as a unit from the patient as the coil was stuck inside the microcatheter.An adequate continuous flush was maintained through the catheters.The procedure was delayed 10 minutes since had to struggle to remove the devices.No medical intervention was required.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PRE-SHAPED PROWLER MICROCATHETERS
Common Device Name
CATHETER, CONTINOUS FLUSH
Manufacturer (Section D)
CODMAN AND SHURTLEFF, INC
325 paramount dr
raynham MA
MDR Report Key6366498
Report Number3008264254-2017-00021
Device Sequence Number861582
Product Code KRA
UDI-Device Identifier10886704028598
UDI-Public(01)10886704028598(17)190831(10)17569016
Combination Product (Y/N)N
Initial Reporter CountryUS
PMA/510(K) Number
K003925
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,health
Initial Reporter Occupation Health Professional
Type of Report Initial
Report Date (Section B) 01/12/2017
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date08/31/2019
Device Catalogue Number606151FX
Device Lot Number17569016
Was Device Available for Evaluation? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 02/28/2017
Initial Report FDA Received Date02/28/2017
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
ORBIT GALAXY COIL
-
-