BARD PERIPHERAL VASCULAR, INC. ULTRAVERSE RX PTA BALLOON DILATATION CATHETER Back to Search Results
Catalog Number U4150310RX
Medical Device Problem Codes Kinked (1339); Retraction Problem (1536); Material Twisted/Bent (2981)
Health Effect - Clinical Code No Consequences Or Impact To Patient (2199)
Date of Event 02/02/2017
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
No hospital/medical records or medical images have been made available to the manufacturer.As the lot number for the device was provided, a review of the device history records is currently being performed.The device has been returned to the manufacturer for evaluation.The investigation of the reported event is currently underway.The information provided by bard represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bard.
 
Event or Problem Description
It was reported that during an angioplasty procedure of a heavily calcified lesion in the sfa, allegedly there was difficulty removing the pta balloon catheter through the sheath after the second inflation.Upon removal from the patient, the pta balloon catheter was found to be kinked.There was no reported patient injury.
 
Additional Manufacturer Narrative
The device history records were reviewed with special attention to the raw materials, subassemblies, manufacturing process and quality control testing.This lot met all release criteria.There was nothing found to indicate there was a manufacturing related cause for this event.Visual/microscopic inspection: the catheter was kinked throughout the balloon portion of the device.Balloon is noted to be twisted.No other anomalies were observed.Functional/performance evaluation: the patency of the guidewire lumen was tested using in-house 0.014¿ guidewire.The guidewire was unable to be fully inserted due to dried blood and poor sample condition.Further functional testing could be performed due to poor sample condition.Medical records review: medical records were not provided; therefore, a review could not be performed.Image/photo review: images/photos were not provided; therefore, a review could not be performed.Conclusion: the device was returned.Based on the condition of the returned device, the investigation is confirmed for a kinked catheter and twisted balloon.The investigation is inconclusive for sheath related retraction issues, due to the poor sample condition.It is likely the reported retraction issues contributed to the kinked catheter and twisted balloon.However, the definitive root cause could not be determined based on the available information.Labeling review: the current (b)(6) ifu (instructions for use) states: warnings: - to prevent vessel damage, the inflated diameter and length of the balloon should approximate the diameter and length of the vessel just proximal and distal to the stenosis.Select a balloon size so that its inflated balloon diameter does not exceed the minimum vessel diameter when diameters of a target vessel vary.[or, it can cause vessel injury.] - when the catheter is exposed to the vascular system, it should be manipulated while under high-quality fluoroscopic observation.Do not advance or retract the catheter unless the balloon is fully deflated.If resistance is met during manipulation, determine the cause of the resistance before proceeding.[applying excessive force to the catheter can cause vessel damage and the catheter can result in tip or catheter breakage, catheter kink or balloon separation.] - do not exceed the rbp recommended for this device.To prevent over pressurization, use of inflation device with manometer is recommended.[balloon rupture may occur if the rbp rating is exceeded.] - careful attention must be paid to the dilatation of calcified lesions or tortuous anatomy.[it may lead to catheter damage or balloon rupture.} prohibitions: - do not reuse.- do not resterilize.The information provided by bard represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bard.
 
Event or Problem Description
It was reported that during an angioplasty procedure of a heavily calcified lesion in the sfa, allegedly there was difficulty removing the pta balloon catheter through the sheath after the second inflation.Upon removal from the patient, the pta balloon catheter was found to be kinked.There was no reported patient injury.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ULTRAVERSE RX PTA BALLOON DILATATION CATHETER
Common Device Name
PTA BALLOON DILATATION CATHETER
Manufacturer (Section D)
BARD PERIPHERAL VASCULAR, INC.
1625 w 3rd st.
tempe AZ 85281
MDR Report Key6366860
Report Number2020394-2017-00129
Device Sequence Number37325
Product Code LIT
UDI-Device Identifier00801741056895
UDI-Public(01)00801741056895(17)180310(10)50120984
Combination Product (Y/N)N
Initial Reporter CountryJA
PMA/510(K) Number
K131199
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source foreign,health professional
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 04/18/2017
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date03/10/2018
Device Catalogue NumberU4150310RX
Device Lot Number50120984
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer02/15/2017
Type of Report(Section G)FDA Requested
Initial Date Received by Manufacturer 03/09/2015
Supplement Date Received by ManufacturerNot provided
Initial Report FDA Received Date02/28/2017
Supplement Report FDA Received Date04/18/2017
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Patient Age80 YR
-
-