Catalog Number 03.010.442
Medical Device Problem Code Failure to Align (2522)
Health Effect - Clinical Code No Known Impact Or Consequence To Patient (2692)
Date of Event 02/03/2017
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
(b)(4).Device is an instrument and is not implanted/explanted.The subject device is not expected to be returned to the synthes manufacturer for evaluation.A device history record review was performed for the subject device lot.Manufacturer: synthes (b)(4).Date of manufacture date: jul 20, 2016.The review showed that there were no issues during the manufacture of the product that would contribute to this complaint condition.No non-conformances were generated during the production of the subject device.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Event or Problem Description
It was reported that while performing a suprapatellar tibial nailing procedure the surgeon had inserted the tibial nail and while attempting to drill for the proximal interlocking screws, the drill bit hit the nail.The surgeon was concerned there was an alignment issue with the synthes aiming devices.The surgeon then attempted to drill for another interlocking screw and was successful.Upon addressing the previous screw, she attempted to drill again and was successful in drilling and placing the screw.The patient also had a distal fibula fracture.While trying to place a bone clamp around the fracture, one tip of the reduction forceps broke off.The fragment was retrieved and discarded.There was a two (2) minute delay due to the reported event.The surgery was completed successfully with another clamp.The patient postsurgical outcome was reportedly fine.Concomitant devices reported: tibial nail (part #unknown, lot # unknown, quantity 1), drill bit (part #unknown lot #unknown, quantity 1).This report is 2 of 4 for (b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
12.0/8.0MM PROTECTION SLEEVE WITH FLATS
Common Device Name
NAIL, FIXATION, BONE
Manufacturer (Section D)
SYNTHES MONUMENT
1051 synthes ave
monument CO 80132
MDR Report Key6371100
Report Number1719045-2017-10168
Device Sequence Number16335894
Product Code JDS
UDI-Device Identifier10886982068842
UDI-Public(01)10886982068842(10)H070242
Combination Product (Y/N)N
Initial Reporter StateTX
Initial Reporter CountryUS
PMA/510(K) Number
K111667
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,health
Initial Reporter Occupation Other
Type of Report Initial
Report Date (Section B) 02/03/2017
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Catalogue Number03.010.442
Device Lot NumberH070242
Was Device Available for Evaluation? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 02/03/2017
Initial Report FDA Received Date03/02/2017
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
UNKNOWN DRILL BIT, QUANTITY 1; UNKNOWN TIBIAL NAIL, QUANTITY 1
Patient Age62 YR
Patient Weight80
-
-