Model Number M00558250
Medical Device Problem Code Bent (1059)
Health Effect - Clinical Code No Consequences Or Impact To Patient (2199)
Date of Event 01/26/2017
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
(b)(4).A visual evaluation of the returned device found the working length of the needle and sheath were kinked at the distal end of the handle and the distal section of the needle was bent.Furthermore, the syringe luer at the handle was cracked.Functional test was performed by injecting water into the device however, water was leaking at the luer connection due to the crack.The reported event of luer damage was confirmed.Based on gathered information, it is most likely that the working length of the needle, sheath and distal section of the needle kinked due to anatomical or procedural factors encountered during the procedure.Therefore, the most probable root cause for the complaint event is operational context.A review of the device history record (dhr) was performed and no deviations were found.A search of the complaint database confirmed that no similar complaints exist for the specified batch.
 
Event or Problem Description
It was reported to boston scientific corporation that expect pulmonary olympus needle was used at station 7 of the patient's airway during an endobronchial ultrasound procedure performed on (b)(6) 2017.According to the complainant, during the procedure after several passes the respiratory therapist was unable to flush air through the needle.Leaking of air was heard at the top of the handle.Reportedly, bubbles were also visible and nothing was flushed out of the distal end of the needle.The procedure was completed with another of the same device.There were no patient complications reported as a result of this event.The patient's condition at the conclusion of the procedure was reported to be fine.The investigation of the returned device found the distal tip of the needle was bent.This is now deemed an mdr reportable event.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
EXPECT PULMONARY OLYMPUS 25GA
Common Device Name
ENDOBRONCHIAL ULTRASOUND TRANSBRONCHIAL ASPIRATION NEEDLE
Manufacturer (Section D)
BOSTON SCIENTIFIC - SPENCER
780 brookside drive
spencer IN 47460
MDR Report Key6385030
Report Number3005099803-2017-00572
Device Sequence Number41719
Product Code EOQ
UDI-Device Identifier08714729861416
UDI-Public(01)08714729861416(17)20191130(10)19934622
Combination Product (Y/N)N
Initial Reporter StateHI
Initial Reporter CountryUS
PMA/510(K) Number
K151315
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,health
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 02/13/2017
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Respiratory Therapist
Device Expiration Date11/30/2019
Device Model NumberM00558250
Device Catalogue Number5825
Device Lot Number19934622
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer01/31/2017
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 02/13/2017
Initial Report FDA Received Date03/07/2017
Patient Sequence Number1
-
-